3.6.13 Maintenance Aging. After conditioning as specified in 4.5.15, connector assemblies
shall meet the subsequent performance requirements specified in Table XI, and shall
show no evidence of damage detrimental to performance or handling.
3.6.14 Random Vibration. When terminated, mated connector assemblies are tested as
specified in 4.5.16, there shall be no electrical discontinuities and no evidence of
cracks, breaks or loosening of parts.
3.6.15 Mechanical Shock
. When terminated, mated connector assemblies are tested as
specified in 4.5.17, there shall be no electrical discontinuities and no evidence of
cracks, breaks, or loosening of parts.
3.6.16 Thermal Shock
. When terminated, mated connector assemblies are tested as specified
in 4.5.18, there shall be no evidence of damage detrimental to performance or handling.
3.6.17 Temperature Life. When terminated, mated connector assemblies are tested as
specified in 4.5.19, the insulation resistance at the maximum rated temperature shall be
1000 megohms minimum.
3.6.18 Humidity. When terminated, mated connector assemblies are tested as specified in
4.5.20, the insulation resistance shall be 100 megohms minimum while at high
humidity and shall be 1000 megohms minimum at the final measurement. The
assemblies shall meet the dielectric withstanding voltage requirements of 3.6.2. at both
measurement times.
3.6.19 Altitude Immersion. When terminated, mated connector assemblies are tested as
specified in 4.5.21, the insulation resistance shall be 1000 megohms minimum, and the
mated connectors shall meet the dielectric withstanding voltage requirements of 3.6.2.
3.6.20 Altitude-Low Temperature. When terminated, mated connector assemblies are tested as
specified in 4.5.22, the connectors shall withstand the applied potential at low pressure with no
evidence of dielectric breakdown. Insulation resistance and dielectric withstanding voltage
requirements at ambient conditions shall be as specified in 3.6.1 and 3.6.2.
3.6.21 Salt Spray. When terminated, mated connector assemblies are tested in accordance
with 4.5.23.1 or 4.5.23.2, the specimens shall show no evidence of damage detrimental
to performance or handling.
3.6.22 Ozone Exposure. When terminated, unmated connector assemblies are tested as
specified in 4.5.24, the connectors shall show no evidence of damage detrimental to
performance or handling.
Tyco Electronics Corporation
300 Constitutional Drive
Menlo Park, CA 94025 USA
No: C-6111
Rev: G
Date: November 5, 1993
Page: 14 of 35
If this document is printed it becomes uncontrolled. Check for the latest revision.
3.6.23 Fluid Immersion. When terminated connector assemblies are tested as specified in
4.5.25, the connectors shall show no evidence of damage detrimental to performance or
handling. Some softening and / or parting of the cable clamp elastomeric strain relief is
permissible as long as functionality is not impaired.
3.6.24 Magnetic Permeability. When unmated connector assemblies are tested as specified in
4.5.26, the relative permeability shall be 2.0 maximum.
3.6.25 Solderability.
(Boxmount connectors with pre-tinned PBC mount tails only). When
unterminated boxmount PCB terminals are tested as specified in 4.5.27, the termination
surfaces of the terminals shall be at least 95 percent covered with a continuous new
solder coating.
3.6.26 Industrial Gas.
When terminated, unmated connector assemblies are tested as specified
in 4.5.28, the connectors shall meet the subsequent performance requirements of Table
X1. The contacts shall show no evidence of damage detrimental to the performance or
handling of the connector.
3.6.27 Contact Inductive Load Switching. When terminated, mated connector assemblies are
tested as specified in 4.5.29, they shall meet the room- temperature, after-conditioning,
contact resistance requirements of Table 111.
3.6.28 Overload Current and Circuit Breaker Compatibility. When terminated, mated
connector assemblies are tested as specified in 4.5.30, the connectors shall meet the
room-temperature, after-conditioning, contact resistance requirements of Table III.
3.6.29 Temperature Rise at Rated Current. When mated connector assemblies are tested as
specified in 4.5.31, the temperature rise shall be 100°C maximum.
3.6.30 Insert Material Requirements.
3.6.30.1 Tensile Strength. When tested as specified in 4.5.32.1, the tensile strength shall be
13,000 psi (90 MPa) minimum.
3.6.30.2 Deflection Temperature.
When tested as specified in 4.5.32.2, the deflection
temperature shall be 185°C minimum.
3.6.30.3 Water Absorption. When tested as specified in 4.5.32.3, the water absorption shall be
0.5 percent maximum.
3.6.30.4 Flammability. When tested as specified in 4.5.32.4, the insert material shall meet the
requirements for U.L. flammability rating 94 V-O.
3.6.30.5 Smoke Generation. When tested in accordance with 4.5.32.5, the corrected specific
optical density shall be 15 maximum for each specimen tested.
Tyco Electronics Corporation
300 Constitutional Drive
Menlo Park, CA 94025 USA
No: C-6111
Rev: G
Date: November 5, 1993
Page: 15 of 35
If this document is printed it becomes uncontrolled. Check for the latest revision.
3.6.31 Insert Impact Resistant. When unterminated pin and socket removable inserts are
tested as specified in 4.5.33, the average uncompensated reversed notch impact strength
for as-molded socket inserts shall be greater than 0.2 ft-lbf (0.27 J), and greater than
0.15 ft-lbf (0.20 J) for as molded pin inserts.
3.6.32 Insert Impact Chip Resistance. When unterminated pin and socket removable inserts
are tested as specified in 4.5.34, there shall be no evidence of chipping or fracture.
3.6.33 Insert Flexure. When unterminated pin and socket removable inserts are tested as
specified in 4.5.35, there shall be no cracking, breaking, or other mechanical
deterioration. Each insert shall then be capable of being placed in a housing, together
with a companion insert when required, and mated with the appropriate mating
connector assembly.
3.6.34 Removable Insert Abuse. After conditioning as specified in 4.5.36, unmated
connectors shall meet the insert retention requirements of 3.6.9, and they shall show no
evidence of damage detrimental to performance or handling.
3.6.35 Retention System Fluid Resistance. When unmated connectors are tested as specified
in 4.5.37, they shall meet the insert retention requirements of 3.6.9.
3.6.36 EME Shielding (EME-Shielded Class Only). When mated connector assemblies
terminated to suitable shielded cable are tested in accordance with 4.5.38, the
maximum surface transfer impedance (Z
t
in milliohms per meter) shall be level 5 as
shown in Figure 1.
3.6.37 Air Leakage (Pressure Maintaining Class Qnly).
When tested in accordance with
4.5.39, connectors shall have a leakage rate of 0.5 atm cm
3
/s maximum.
3.6.38 Gas Tightness.
When terminals with solderless wrap connections are tested in
accordance with 4.5.40, the connections shall meet the gas tightness requirements of
MIL-STD-1130.
3.6.39 Strip Force. When terminals with solderless wrap connections are tested in accordance
with 4.5.41, the connections shall meet the strip force requirements of MIL-STD-1130.
3.6.40 Wrapper Resistance. When terminals with solderless wrap connections are tested in
accordance with 4.5.42, the connections shall meet the wrapper resistance requirements
of MIL-STD-1130.
3.6.41 Cold Handling. When connectors are tested as specified in 4.5.43 there shall be no
visible material deterioration. Connectors shall be able to be mated and demated
normally and removable inserts shall be able to be removed and installed normally.

MTCST-YH2-R03

Mfr. #:
Manufacturer:
TE Connectivity
Description:
Rack & Panel Connectors MTCST-YH2-R03
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union