Tyco Electronics Corporation
300 Constitutional Drive
Menlo Park, CA 94025 USA
No: C-6111
Rev: G
Date: November 5, 1993
Page: 16 of 35
If this document is printed it becomes uncontrolled. Check for the latest revision.
Figure 1. Surface Transfer Impedance
3.6.42 Post Test Examination. Connector assemblies shall be inspected as specified in 4.5.44.
Any evidence of the effects described in 4.5.44 shall constitute failure.
3.7 Product Identification.
All marking shall be in accordance with the applicable
specification control drawing. The marking shall remain legible after completion of the
test sequences in Groups 1, 2, 3, and 4 of Table XI.
Tyco Electronics Corporation
300 Constitutional Drive
Menlo Park, CA 94025 USA
No: C-6111
Rev: G
Date: November 5, 1993
Page: 17 of 35
If this document is printed it becomes uncontrolled. Check for the latest revision.
3.7.1 Shell Identification. Connector shells shall be marked on an external surface with the
shell part number, date code, and the name "Raychem." The top and bottom surfaces of
every shall designed for removable inserts shall be permanently marked at the wire
termination end to identify proper insert orientation.
3.7.2 Removable Insert Identification. Removable inserts shall be marked with the part
number, date code, the name "Raychem," and an orientation indicator as specified in
the applicable specification sheet.
3.7.2.1 Contact Identification. The number "1" contact shall be marked on the engaging face
of each insert. The first and last contact positions shall be permanently identified on the
keyed surface of each removable insert.
3.8 Workmanship. Connectors and accessories shall be processed in such a manner as to
be uniform in quality; they shall be free from burrs, cracks, voids, chips, blisters, sharp
cutting edges, and other defects that would adversely affect life or serviceability.
4.0 Quality Assurance Provisions
4.1 Responsibility for Inspection. The supplier is responsible for the performance of all
inspection tests specified herein. The supplier may utilize his own or any other suitable
testing facility. Inspection records of the tests shall be kept complete and available to
the buyer as specified in the contract or order.
4.1.1 Test Equipment and Inspection Facilities. Test and measuring equipment and
inspection facilities of sufficient accuracy, quality, and quantity to permit performance
of the required inspection shall be established and maintained by the supplier. A
calibration system to control the accuracy of the measuring and test equipment shall be
maintained in accordance with MIL-STD-45662.
4.2 Classification of Inspections. The examination and testing of connectors covered by
this specification shall be classified as follows:
a. Qualification inspection (See para. 4.3)
b. Acceptance inspection (See para. 4.4)
4.3 Qualification Inspection. Qualification inspection shall consist of the tests in Table XI.
Qualification shall be granted upon successful completion of the inspections and tests
of Table XI, conducted upon the samples of Table X, in accordance with Specification
C-6100. In Table XI test groups where the tests are not sequential, separate samples
shall be used for each test.
Tyco Electronics Corporation
300 Constitutional Drive
Menlo Park, CA 94025 USA
No: C-6111
Rev: G
Date: November 5, 1993
Page: 18 of 35
If this document is printed it becomes uncontrolled. Check for the latest revision.
4.3.1 Test Samples for Qualification Inspection. Test samples, submitted for qualification
inspection, shall be produced using equipment and procedures normally used in
production. Test samples shall be of the types listed in Table X. Individual test samples
shall be selected in compliance with the qualification requirements of Specification C-
6100.
Table X. Qualification Test Samples
Test
Group
Type of Test Sample
1 Terminated mated connectors
2 Terminated mated connectors
3 Terminated mated connectors
4 Terminated mated connectors
5 Terminated mated connectors
6 Terminated mated connectors (EME-shielded class only)
7 Terminated mated connectors (Cadmium shell plating only)
8 Inserts or Boxmounts w/ PCB mount tails (Solderability)
9 Insert Material Specimans
10 Removable Inserts
11 Terminated mated connectors
12 Terminated mated connectors
S-1 Terminated mated connectors (Non-Standard Configurations)
4.3.2 Failures.
One or more failures of the tests listed in Table XI shall be cause for failure
of qualification of the parts under test. An exception to this is visual examination,
where occurrence of one major defect or two minor defects shall be cause for failure of
qualification. Major and minor defects shall be as defined in MIL-STD-105. In the
event of failure, procedures outlined in Raychem Specification C-6100 shall be
followed.
4.3.3 Qualification Report. Qualification shall be documented in a report which shall be
available to the buyer.

MTCST-YH2-R03

Mfr. #:
Manufacturer:
TE Connectivity
Description:
Rack & Panel Connectors MTCST-YH2-R03
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union