ZSSC3138
© 2016 Integrated Device Technology, Inc.
1 Electrical Characteristics
1.1. Absolute Maximum Ratings
Parameters apply in operation temperature range and without time limitations.
Table 1.1 Absolute Maximum Ratings
No. Parameter Symbol Conditions Min Max Unit
1.1.1 Supply voltage
VDDE
AMR
To VSSE, refer to
section 3 for application
circuits
-33 33 VDC
1.1.2 Potential at AOUT pin
1)
V
OUT
Referenced to VSSE -33 33 VDC
1.1.3 Analog supply voltage
1)
VDDA
AMR
Referenced to VSSA,
VDDE - VDDA < 0.35V
-0.3 6.5 VDC
1.1.4 Voltage at all analog and
digital IO pins
V
A_IO
V
D_IO
Referenced to VSSA -0.3 VDDA + 0.3 VDC
1.1.5 Storage temperature T
STG
-55 150
°C
1) Refer to the ZSSC313x High Voltage Protection Description for specification and detailed conditions.
1.2. Operating Conditions
All voltages are referenced to VSSA.
Table 1.2 Operating Conditions
No. Parameter Symbol Conditions Min Typ Max Unit
1.2.1 Ambient temperature
T
AMB_TQE
Extended Temperature
Range (TQE)
-40 150
°C
T
AMB_TQA
Advanced-Performance
Temperature Range
(TQA)
-40 125
°C
T
AMB_TQI
Best-Performance
Temperature Range (TQI)
-25 85
°C
1.2.2 Supply voltage VDDE 4.5 5.0 5.5 VDC
1.2.3 Bridge resistance
3) 4)
R
BR
2 25
kΩ
1) Maximum operation temperature range depends on product version (refer to section 8).
2) See the temperature profile description in the ZSSC313x Dice Package Document.
3) No measurement in mass production, parameter is guaranteed by design and/or quality observation.
4) Symmetric behavior and identical electrical properties (especially the low pass characteristic) of both sensor inputs of the ZSSC3138 are required.
Unsymmetrical conditions of the sensor and/or external components connected to the sensor input pins of the ZSSC3138 can generate a failure in
signal operation.