MAX1026/MAX1028/MAX1030
10-Bit 300ksps ADCs with FIFO,
Temp Sensor, Internal Reference
10 ______________________________________________________________________________________
Converter Operation
The MAX1026/MAX1028/MAX1030 ADCs use a fully dif-
ferential, successive-approximation register (SAR) con-
version technique and an on-chip T/H block to convert
temperature and voltage signals into a 10-bit digital
result. Both single-ended and differential configurations
are supported, with a unipolar signal range for single-
ended mode and bipolar or unipolar ranges for differ-
ential mode.
Input Bandwidth
The ADC’s input-tracking circuitry has a 1MHz small-
signal bandwidth, so it is possible to digitize high-
speed transient events and measure periodic signals
with bandwidths exceeding the ADC’s sampling rate by
using undersampling techniques. Anti-alias prefiltering
of the input signals is necessary to avoid high-frequen-
cy signals aliasing into the frequency band of interest.
Analog Input Protection
Internal ESD protection diodes clamp all pins to V
DD
and GND, allowing the inputs to swing from (GND -
0.3V) to (V
DD
+ 0.3V) without damage. However, for
accurate conversions near full scale, the inputs must
not exceed V
DD
by more than 50mV or be lower than
GND by 50mV. If an off-channel analog input voltage
exceeds the supplies, limit the input current to 2mA.
3-Wire Serial Interface
The MAX1026/MAX1028/MAX1030 feature a serial
interface compatible with SPI/QSPI and MICROWIRE
devices. For SPI/QSPI, ensure the CPU serial interface
runs in master mode so it generates the serial clock
signal. Select the SCLK frequency of 10MHz or less,
and set clock polarity (CPOL) and phase (CPHA) in the
μP control registers to the same value. The MAX1026/
MAX1028/MAX1030 operate with SCLK idling high or
low, and thus operate with CPOL = CPHA = 0 or CPOL
= CPHA = 1. Set CS low to latch input data at DIN on
the rising edge of SCLK. Output data at DOUT is
updated on the falling edge of SCLK. Bipolar true-dif-
ferential results and temperature sensor results are
available in two’s complement format, while all others
are in binary.
Serial communication always begins with an 8-bit input
data byte (MSB first) loaded from DIN. Send a second
byte, immediately following the setup byte, to write to
the unipolar mode or bipolar mode registers (see
Tables 1, 3, 4, and 5). A high-to-low transition on CS ini-
tiates the data input operation. The input data byte and
the subsequent data bytes are clocked from DIN into
the serial interface on the rising edge of SCLK.
Tables 1–7 detail the register descriptions. Bits 5 and 4,
CKSEL1 and CKSEL0, respectively, control the clock
modes in the setup register (see Table 3). Choose
between four different clock modes for various ways to
start a conversion and determine whether the acquisi-
tions are internally or externally timed. Select clock
mode 00 to configure CNVST/AIN_ to act as a conver-
sion start and use it to request the programmed inter-
nally timed conversions without tying up the serial bus.
In clock mode 01, use CNVST to request conversions
one channel at a time, controlling the sampling speed
without tying up the serial bus. Request and start inter-
nally timed conversions through the serial interface by
writing to the conversion register in the default clock
mode, 10. Use clock mode 11 with SCLK up to 4.8MHz
for externally timed acquisitions to achieve sampling
rates up to 300ksps. Clock mode 11 disables scanning
and averaging. See Figures 4–7 for timing specifica-
tions and how to begin a conversion.
These devices feature an active-low, end-of-conversion
output. EOC goes low when the ADC completes the
last-requested operation and is waiting for the next
input data byte (for clock modes 00 and 10). For clock
mode 01, EOC goes low after the ADC completes each
requested operation. EOC goes high when CS or CNVST
goes low. EOC is always high in clock mode 11.
Single-Ended/Differential Input
The MAX1026/MAX1028/MAX1030 use a fully differen-
tial ADC for all conversions. The analog inputs can be
configured for either differential or single-ended con-
versions by writing to the setup register (see Table 3).
Single-ended conversions are internally referenced to
GND (see Figure 3).
In differential mode, the T/H samples the difference
between two analog inputs, eliminating common-mode
DC offsets and noise. IN+ and IN- are selected from
the following pairs: AIN0/AIN1, AIN2/AIN3, AIN4/AIN5,
AIN6/AIN7, AIN8/AIN9, AIN10/AIN11, AIN12/AIN13,
and AIN14/AIN15. AIN0–AIN7 are available on the
MAX1026, MAX1028, and MAX1030. AIN8–AIN11 are
only available on the MAX1028 and MAX1030.
AIN12–AIN15 are only available on the MAX1030. See
Tables 2–5 for more details on configuring the inputs.
For the inputs that can be configured as CNVST or an
analog input, only one can be used at a time. For the
inputs that can be configured as REF- or an analog
input, the REF- configuration excludes the analog input.
MAX1026/MAX1028/MAX1030
10-Bit 300ksps ADCs with FIFO,
Temp Sensor, Internal Reference
______________________________________________________________________________________ 11
Unipolar/Bipolar
Address the unipolar and bipolar registers through the
setup register (bits 1 and 0). Program a pair of analog
channels for differential operation by writing a 1 to the
appropriate bit of the bipolar or unipolar register.
Unipolar mode sets the differential input range from 0 to
V
REF
. A negative differential analog input in unipolar
mode causes the digital output code to be zero.
Selecting bipolar mode sets the differential input range
to ±V
REF
/ 2. The digital output code is binary in unipo-
lar mode and two’s complement in bipolar mode (see
the transfer function graphs, Figures 8 and 9).
In single-ended mode, the MAX1026/MAX1028/
MAX1030 always operate in unipolar mode. The analog
inputs are internally referenced to GND with a full-scale
input range from 0 to V
REF
.
True Differential Analog Input T/H
The equivalent circuit of Figure 3 shows the
MAX1026/MAX1028/MAX1030s’ input architecture. In
track mode, a positive input capacitor is connected to
AIN0–AIN15 in single-ended mode (and AIN0, AIN2,
AIN4…AIN14 in differential mode). A negative input
capacitor is connected to GND in single-ended mode
(or AIN1, AIN3, AIN5…AIN15 in differential mode). For
external track-and-hold timing, use clock mode 01.
After the T/H enters hold mode, the difference between
the sampled positive and negative input voltages is
converted. The time required for the T/H to acquire an
input signal is determined by how quickly its input
capacitance is charged. If the input signal’s source
impedance is high, the required acquisition time length-
ens. The acquisition time, t
ACQ
, is the maximum time
needed for a signal to be acquired, plus the power-up
time. It is calculated by the following equation:
where R
IN
= 1.5kΩ, R
S
is the source impedance of the
input signal, and t
PWR
= 1μs, the power-up time of the
device. The varying power-up times are detailed in the
explanation of the clock mode conversions.
t
ACQ
is never less than 1.4μs, and any source imped-
ance below 300Ω does not significantly affect the
ADC’s AC performance. A high-impedance source can
be accommodated either by lengthening t
ACQ
or by
placing a 1μF capacitor between the positive and neg-
ative analog inputs.
Internal FIFO
The MAX1026/MAX1028/MAX1030 contain a FIFO
buffer that can hold up to 16 ADC results plus one tem-
perature result. This allows the ADC to handle multiple
internally clocked conversions and a temperature mea-
surement, without tying up the serial bus.
If the FIFO is filled and further conversions are request-
ed without reading from the FIFO, the oldest ADC
results are overwritten by the new ADC results. Each
result contains 2 bytes, with the MSB preceded by 4
leading zeros and the LSB followed by 2 sub-bits. After
each falling edge of CS, the oldest available byte of
data is available at DOUT, MSB first. When the FIFO is
empty, DOUT is zero.
The first 2 bytes of data read out after a temperature mea-
surement always contain the temperature result preceded
by 4 leading zeros, MSB first. If another temperature mea-
surement is performed before the first temperature result
is read out, the old measurement is overwritten by the
new result. Temperature results are in degrees Celsius
(two’s complement) at a resolution of 1/8 of a degree. See
the
Temperature Measurements
section for details on
converting the digital code to a temperature.
Internal Clock
The MAX1026/MAX1028/MAX1030 operate from an inter-
nal oscillator, which is accurate within 10% of the
4.4MHz nominal clock rate. The internal oscillator is
active in clock modes 00, 01, and 10. Read out the data
at clock speeds up to 10MHz. See Figures 4–7 for details
on timing specifications and starting a conversion.
txRRxpFt
AQC S IN PWR
=+
()
+924
+
-
HOLD
CIN+
REF
GND
DAC
CIN-
V
DD
/2
COMPARATOR
AIN0-AIN15
(SINGLE ENDED);
AIN0, AIN2,
AIN4…AIN14
(DIFFERENTIAL)
GND
(SINGLE ENDED);
AIN1, AIN3,
AIN5…AIN15
(DIFFERENTIAL)
HOLD
HOLD
Figure 3. Equivalent Input Circuit
MAX1026/MAX1028/MAX1030
10-Bit 300ksps ADCs with FIFO,
Temp Sensor, Internal Reference
12 ______________________________________________________________________________________
Applications Information
Register Descriptions
The MAX1026/MAX1028/MAX1030 communicate
between the internal registers and the external circuitry
through the SPI/QSPI-compatible serial interface. Table
1 details the registers and the bit names. Tables 2–7
show the various functions within the conversion regis-
ter, setup register, averaging register, reset register,
unipolar register, and bipolar register.
Conversion Time Calculations
The conversion time for each scan is based on a num-
ber of different factors: conversion time per sample,
samples per result, results per scan, if a temperature
measurement is requested, and if the external refer-
ence is in use.
Use the following formula to calculate the total conver-
sion time for an internally timed conversion in clock
modes 00 and 10 (see the
Electrical Characteristics
section as applicable):
total conversion time = t
cnv
x n
avg
x n
result
+ t
TS
+ t
RP
where:
t
cnv
= t
acq
(max) + t
conv
(max)
n
avg
= samples per result (amount of averaging)
n
result
= number of FIFO results requested; determined
by number of channels being scanned or by NSCAN1,
NSCAN0
t
TS
= time required for temperature measurement; set
to zero if temp measurement is not requested
t
RP
= internal reference wake-up; set to zero if the inter-
nal reference is already powered up or if the external
reference is being used
In clock mode 01, the total conversion time depends on
how long CNVST is held low or high, including any time
required to turn on the internal reference. Conversion
time in externally clocked mode (CKSEL1, CKSEL0 = 11)
depends on the SCLK period and how long CS is held
high between each set of eight SCLK cycles.
Conversion Register
Select active analog input channels, scan modes, and
a single temperature measurement per scan by writing
to the conversion register. Table 2 details channel
selection, the four scan modes, and how to request a
temperature measurement. Request a scan by writing
to the conversion register when in clock mode 10 or 11,
or by applying a low pulse to the CNVST pin when in
clock mode 00 or 01.
A conversion is not performed if it is requested on a
channel that has been configured as CNVST or REF-.
Do not request conversions on channels 8–15 on the
MAX1026 and channels 12–15 on the MAX1028. Set
CHSEL3:CHSEL0 to the lower channel’s binary value. If
the last two channels are configured as a differential
pair and one of them has been reconfigured as CNVST
or REF-, the pair is ignored.
Select scan mode 00 or 01 to return one result per sin-
gle-ended channel and one result per differential pair
within the requested range, plus one temperature result if
selected. Select scan mode 10 to scan a single input
channel numerous times, depending on NSCAN1 and
NSCAN0 in the averaging register (Table 6). Select scan
mode 11 to return only one result from a single channel.
REGISTER NAME BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0
Conversion 1 CHSEL3 CHSEL2 CHSEL1 CHSEL0 SCAN1 SCAN0 TEMP
Setup 0 1 CKSEL1 CKSEL0 REFSEL1 REFSEL0 DIFFSEL1 DIFFSEL0
Averaging 0 0 1 AVGON NAVG1 NAVG0 NSCAN1 NSCAN0
Reset 0 0 0 1 RESET XXX
Unipolar mode (setup) UCH0/1 UCH2/3 UCH4/5 UCH6/7 UCH8/9* UCH10/11* UCH12/13** UCH14/15**
Bipolar mode (setup) BCH0/1 BCH1/2 BCH4/5 BCH6/7 BCH8/9* BCH10/11* BCH12/13** BCH14/15**
Table 1. Input Data Byte (MSB First)
*
Unipolar/bipolar channels 8–15 are only valid on the MAX1028 and MAX1030.
**
Unipolar/bipolar channels 12–15 are only valid on the MAX1030.