MAX1026/MAX1028/MAX1030
10-Bit 300ksps ADCs with FIFO,
Temp Sensor, Internal Reference
16 ______________________________________________________________________________________
BIT NAME BIT FUNCTION
7 (MSB) Set to zero to select averaging register.
6 Set to zero to select averaging register.
5 Set to 1 to select averaging register.
AVGON 4 Set to 1 to turn averaging on. Set to zero to turn averaging off.
NAVG1 3 Configures the number of conversions for single-channel scans.
NAVG0 2
Configures the number of conversions for single-channel scans.
NSCAN1 1 Single-channel scan count. (Scan mode 10 only.)
NSCAN0 0 (LSB) Single-channel scan count. (Scan mode 10 only.)
Table 6. Averaging Register*
AVGON NAVG1 NAVG0 FUNCTION
0 x x Performs 1 conversion for each requested result.
1 0 0 Performs 4 conversions and returns the average for each requested result.
1 0 1 Performs 8 conversions and returns the average for each requested result.
1 1 0 Performs 16 conversions and returns the average for each requested result.
1 1 1 Performs 32 conversions and returns the average for each requested result.
NSCAN1 NSCAN0 FUNCTION (APPLIES ONLY IF SCAN MODE 10 IS SELECTED)
0 0 Scans channel N and returns 4 results.
0 1 Scans channel N and returns 8 results.
1 0 Scans channel N and returns 12 results.
1 1 Scans channel N and returns 16 results.
BIT NAME BIT FUNCTION
7 (MSB) Set to zero to select reset register.
6 Set to zero to select reset register.
5 Set to zero to select reset register.
4 Set to 1 to select reset register.
RESET 3 Set to zero to reset all registers. Set to 1 to clear the FIFO only.
x 2 Reserved. Don’t care.
x 1 Reserved. Don’t care.
x 0 (LSB) Reserved. Don’t care.
Table 7. Reset Register
*
See below for bit details.
MAX1026/MAX1028/MAX1030
10-Bit 300ksps ADCs with FIFO,
Temp Sensor, Internal Reference
______________________________________________________________________________________ 17
Internally Timed Acquisitions and
Conversions Using
CNVST
Performing Conversions in Clock Mode 00
In clock mode 00, the wake up, acquisition, conversion,
and shutdown sequences are initiated through CNVST
and performed automatically using the internal oscilla-
tor. Results are added to the internal FIFO to be read
out later. See Figure 4 for clock mode 00 timing.
Initiate a scan by setting CNVST low for at least 40ns
before pulling it high again. The MAX1026/MAX1028/
MAX1030 then wake up, scan all requested channels,
store the results in the FIFO, and shut down. After the
scan is complete, EOC is pulled low and the results are
available in the FIFO. Wait until EOC goes low before
pulling CS low to communicate with the serial interface.
EOC stays low until CS or CNVST is pulled low again. A
temperature measurement result, if requested, pre-
cedes all other FIFO results.
Do not initiate a second CNVST before EOC goes low;
otherwise, the FIFO can become corrupted.
Externally Timed Acquisitions and
Internally Timed Conversions with
CNVST
Performing Conversions in Clock Mode 01
In clock mode 01, conversions are requested one at a
time using CNVST and performed automatically using
the internal oscillator. See Figure 5 for clock mode 01
timing.
Setting CNVST low begins an acquisition, wakes up the
ADC, and places it in track mode. Hold CNVST low for
at least 1.4μs to complete the acquisition. If the internal
reference needs to wake up, an additional 65μs is
required for the internal reference to power up. If a tem-
perature measurement is being requested, reference
power-up and temperature measurement are internally
timed. In this case, hold CNVST low for at least 40ns.
Set CNVST high to begin a conversion. After the con-
version is complete, the ADC shuts down and pulls
EOC low. EOC stays low until CS or CNVST is pulled
low again. Wait until EOC goes low before pulling CS or
CNVST low.
If averaging is turned on, multiple CNVST pulses need
to be performed before a result is written to the FIFO.
Once the proper number of conversions has been per-
formed to generate an averaged FIFO result, as speci-
fied by the averaging register, the scan logic
automatically switches the analog input multiplexer to
the next-requested channel. If a temperature measure-
ment is programmed, it is performed after the first rising
edge of CNVST following the input data byte written to
the conversion register. The result is available on DOUT
once EOC has been pulled low.
(UP TO 514 INTERNALLY CLOCKED ACQUISITIONS AND CONVERSIONS)
CS
DOUT
MSB1
LSB1 MSB2
SCLK
CNVST
EOC
SET CNVST LOW FOR AT LEAST 40ns TO BEGIN A CONVERSION. X = DON'T CARE.
Figure 4. Clock Mode 00
MAX1026/MAX1028/MAX1030
10-Bit 300ksps ADCs with FIFO,
Temp Sensor, Internal Reference
18 ______________________________________________________________________________________
Internally Timed Acquisitions and
Conversions Using the Serial Interface
Performing Conversions in Clock Mode 10
In clock mode 10, the wake-up, acquisition, conversion,
and shutdown sequences are initiated by writing an
input data byte to the conversion register, and are per-
formed automatically using the internal oscillator. This
is the default clock mode upon power-up. See Figure 6
for clock mode 10 timing.
Initiate a scan by writing a byte to the conversion regis-
ter. The MAX1026/MAX1028/MAX1030 then power up,
scan all requested channels, store the results in the
FIFO, and shut down. After the scan is complete, EOC
is pulled low and the results are available in the FIFO. If
a temperature measurement is requested, the tempera-
ture result precedes all other FIFO results. EOC stays
low until CS is pulled low again.
CS
DOUT
SCLK
CNVST
EOC
(CONVERSION2)
MSB1
LSB1
MSB2
(ACQUISITION1)
(ACQUISITION2)
(CONVERSION1)
REQUEST MULTIPLE CONVERSIONS BY SETTING CNVST LOW FOR EACH CONVERSION. X = DON'T CARE.
Figure 5. Clock Mode 01
(UP TO 514 INTERNALLY CLOCKED ACQUISITIONS AND CONVERSIONS)
MSB1
LSB1
MSB2
(CONVERSION BYTE)
CS
DOUT
SCLK
DIN
EOC
THE CONVERSION BYTE BEGINS THE ACQUISITION. CNVST IS NOT REQUIRED. X = DON'T CARE.