IXYS Reserves the Right to Change Limits, Test Conditions, and Dimensions.
MMIX1X200N60B3H1
IXYS REF: MMIX1X200N60B3(91) 6-13-12
Fig. 22. Typ. Forward characteristics
0
20
40
60
80
100
120
140
160
180
200
0 0.5 1 1.5 2 2.5 3 3.5 4
V
F
- [V]
I
F
[A]
T
VJ
= 25ºC
T
VJ
= 150ºC
Fig. 24. Typ. Peak Reverse Current I
RM
vs. -di
F
/dt
40
60
80
100
120
140
1000 1100 1200 1300 1400 1500 1600 1700 1800 1900
di
F
/dt [A/µs]
I
RM
[A]
T
VJ
= 150ºC
V
R
= 300V
200A
50A
100A
Fig. 25. Typ. Recovery Time t
rr
vs. -di
F
/dt
50
100
150
200
250
300
350
1000 1100 1200 1300 1400 1500 1600 1700 1800 1900
-di
F
/dt [A/µs]
t
rr
[ns]
T
VJ
= 150ºC
V
R
= 300V
200A
50A
100A
Fig. 26. Typ. Recovery Energy E
rec
vs. -di
F
/dt
0
1
2
3
4
5
1000 1100 1200 1300 1400 1500 1600 1700 1800 1900
-di
F
/dt [A/µs]
E
rec
[mJ]
T
VJ
= 150ºC
V
R
= 300V
200A
50A
100A
Fig. 23. Typ. Reverse Recovery Charge Q
rr
vs. -di
F
/dt
4
6
8
10
12
14
16
18
20
1000 1100 1200 1300 1400 1500 1600 1700 1800 1900
-di
F
/ dt [A/µs]
Q
rr
[µC]
T
VJ
= 150ºC
V
R
= 300V
200A
50A
100A