ADUM3210TRZ-EP

Enhanced Product ADuM3210-EP/ADuM3211-EP
Rev. A | Page 7 of 12
PACKAGE CHARACTERISTICS
Table 13.
Parameter Symbol Min Typ Max Unit Test Conditions/Comments
Resistance (Input-to-Output)
1
R
I-O
10
12
Capacitance (Input-to-Output)
1
C
I-O
1.0 pF f = 1 MHz
Input Capacitance C
I
4.0 pF
IC Junction-to-Case Thermal Resistance, Side 1 θ
JCI
46 °C/W Thermocouple located at center
of package underside
IC Junction-to-Case Thermal Resistance, Side 2 θ
JCO
41 °C/W
1
The device is considered a 2-terminal device; Pin 1 through Pin 4 are shorted together, and Pin 5 through Pin 8 are shorted together.
REGULATORY INFORMATION
The ADuM3210-EP/ADuM3211-EP are pending approval by the organizations listed in Table 14.
Table 14.
UL (Pending) CSA (Pending) VDE (Pending)
Recognized under UL 1577
component recognition program
1
Approved under CSA Component Acceptance Notice #5A Certified according to DIN V VDE V 0884-10
(VDE V 0884-10):2006-12
2
Single/basic 2500 V rms
isolation voltage
Basic insulation per CSA 60950-1-03 and IEC 60950-1,
400 V rms (566 V peak) maximum working voltage
Reinforced insulation, 560 V peak
Functional insulation per CSA 60950-1-03 and IEC 60950-1,
800 V rms (1131 V peak) maximum working voltage
File E214100 File 205078 File 2471900-4880-0001
1
In accordance with UL 1577, each ADuM3210-EP/ADuM3211-EP is proof tested by applying an insulation test voltage ≥ 3000 V rms for 1 sec.
2
In accordance with DIN V VDE V 0884-10 (VDE V 0884-10):2006-12, each ADuM3210-EP/ADuM3211-EP is proof tested by applying an insulation test voltage ≥ 1050 V peak
for 1 sec (partial discharge detection limit = 5 pC). The asterisk (*) marking branded on the component designates DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 15.
Parameter Symbol Value Unit Test Conditions/Comments
Rated Dielectric Insulation Voltage 2500 V rms 1-minute duration
Minimum External Air Gap (Clearance) L(I01) 4.0 mm min Measured from input terminals to output terminals,
shortest distance through air, in the plane of the PCB
Minimum External Tracking (Creepage) L(I02) 4.0 mm min Measured from input terminals to output terminals,
shortest distance path along body
Minimum Internal Distance (Internal Clearance) 0.017 min mm min Insulation distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >400 V DIN IEC 112/VDE 0303, Part 1
Isolation Group II Material Group (DIN VDE 0110, 1/89, Table 1)
ADuM3210-EP/ADuM3211-EP Enhanced Product
Rev. A | Page 8 of 12
INSULATION CHARACTERISTICS (DIN V VDE V 0884-10 (VDE V 0884-10):2006-12)
These isolators are suitable for reinforced isolation only within the safety limit data. Maintenance of the safety data is ensured by protective
circuits. The asterisk (*) marking branded on the component designates DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 approval for
a 560 V peak working voltage.
Table 16.
Description Test Conditions/Comments Symbol Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤ 150 V rms I to IV
For Rated Mains Voltage ≤ 300 V rms I to III
For Rated Mains Voltage 400 V rms I to II
Climatic Classification 40/125/21
Pollution Degree per DIN VDE 0110, Table 1
2
Maximum Working Insulation Voltage V
IORM
560 V peak
Input-to-Output Test Voltage, Method B1 V
IORM
× 1.875 = V
PR
, 100% production test, t
m
= 1 sec,
partial discharge < 5 pC
V
PR
1050 V peak
Input-to-Output Test Voltage, Method A
After Environmental Tests Subgroup 1 V
IORM
× 1.6 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC V
PR
896 V peak
After Input and/or Safety Tests
Subgroup 2 and Subgroup 3
V
IORM
× 1.2 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC V
PR
672 V peak
Highest Allowable Overvoltage Transient overvoltage, t
TR
= 10 sec V
TR
4000 V peak
Surge Isolation Voltage
V
PEAK
= 10 kV, 1.2 µs rise time, 50 µs, 50% fall time
V
IOSM
4000 V peak
Safety-Limiting Values
Maximum value allowed in the event of a failure
(see Figure 3)
Case Temperature T
S
150 °C
Total Power Dissipation at 25°C
P
S
1.56 W
Insulation Resistance at T
S
V
IO
= 500 V R
S
>10
9
CASE TEMPERATURE (°C)
SAFETY-LIMITING CURRENT (mA)
0
0
200
180
100
80
60
40
20
50
100 150 200
SIDE 1
SIDE 2
120
140
160
13094-002
Figure 3. Thermal Derating Curve, Dependence of Safety-Limiting Values on
Case Temperature per DIN V VDE V 0884-10
RECOMMENDED OPERATING CONDITIONS
Table 17.
Parameter Symbol Rating
Operating Temperature T
A
−55°C to +125°C
Supply Voltages
1
V
DD1
, V
DD2
3 V to 5.5 V
Maximum Input Signal Rise and
Fall Times
1 ms
Start-Up Current
I
DD1
, I
DD2
20 mA
1
All voltages are relative to their respective ground.
Enhanced Product ADuM3210-EP/ADuM3211-EP
Rev. A | Page 9 of 12
ABSOLUTE MAXIMUM RATINGS
T
A
= 25°C, unless otherwise noted.
Table 18.
Parameter Rating
Storage Temperature (T
ST
) 55°C to +150°C
Ambient Operating Temperature (T
A
) −55°C to +125°C
Supply Voltages (V
DD1
, V
DD2
)
1
−0.5 V to +7.0 V
Input Voltage (V
IA
, V
IB
)
1, 2
−0.5 V to V
DDI
+ 0.5 V
Output Voltage (V
OA
, V
OB
)
1, 2
0.5 V to V
DDO
+ 0.5 V
Average Output Current per Pin (I
O
)
3
−22 mA to +22 mA
Common-Mode Transients
(CM
H
, CM
L
)
4
−100 kV/µs to +100 kV/µs
1
Each voltage is relative to its respective ground.
2
V
DDI
and V
DDO
refer to the supply voltages on the input and output sides
of a given channel, respectively.
3
See Figure 3 for maximum allowable current values for various temperatures.
4
Refers to common-mode transients across the insulation barrier. Common-
mode transients exceeding the absolute maximum rating can cause latch-up
or permanent damage.
Stresses at or above those listed under Absolute Maximum
Ratings may cause permanent damage to the product. This is a
stress rating only; functional operation of the product at these
or any other conditions above those indicated in the operational
section of this specification is not implied. Operation beyond
the maximum operating conditions for extended periods may
affect product reliability.
Table 19. Maximum Continuous Working Voltage
Parameter Max Unit Constraint
AC Voltage, Bipolar
Waveform
565 V peak 50-year minimum
lifetime
AC Voltage, Unipolar
Waveform
Functional Insulation 1131 V peak Maximum approved
working voltage per
IEC 60950-1
Basic Insulation
560
V peak
Maximum approved
working voltage per
IEC 60950-1 and
VDE V 0884-10
DC Voltage
Functional Insulation
1131
V peak
Maximum approved
working voltage per
IEC 60950-1
Basic Insulation 560 V peak Maximum approved
working voltage per
IEC 60950-1 and
VDE V 0884-10
ESD CAUTION

ADUM3210TRZ-EP

Mfr. #:
Manufacturer:
Analog Devices Inc.
Description:
Digital Isolators DUAL-CHANNEL DIGITAL ISOLATORS
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: