7
Solder Reow Temperature Prole
Recommended Pb-Free IR Prole
0
TIME (SECONDS)
TEMPERATURE (°C)
200
100
50 150100 200 250
300
0
30
SEC.
50 SEC.
30
SEC.
160 °C
140 °C
150 °C
PEAK
TEMP.
245 °C
PEAK
TEMP.
240 °C
PEAK
TEMP.
230 °C
SOLDERING
TIME
200 °C
PREHEATING TIME
150 °C, 90 + 30 SEC.
2.5 C ± 0.5 °C/SEC.
3 °C + 1 °C/–0.5 °C
TIGHT
TYPICAL
LOOSE
ROOM
TEMPERATURE
PREHEATING RATE 3 °C + 1 °C/–0.5 °C/SEC.
REFLOW HEATING RATE 2.5 °C ± 0.5 °C/SEC.
NOTE: NON-HALIDE FLUX SHOULD BE USED.
217 °C
RAMP-DOWN
6 °C/SEC. MAX.
RAMP-UP
3 °C/SEC. MAX.
150 - 200 °C
* 260 +0/-5 °C
t 25 °C to PEAK
60 to 150 SEC.
15 SEC.
TIME WITHIN 5 °C of ACTUAL
PEAK TEMPERATURE
t
p
t
s
PREHEAT
60 to 180 SEC.
t
L
T
L
T
smax
T
smin
25
T
p
TIME
TEMPERATURE
NOTES:
THE TIME FROM 25 °C to PEAK TEMPERATURE = 8 MINUTES MAX.
T
smax
= 200 °C, T
smin
= 150 °C
NOTE: NON-HALIDE FLUX SHOULD BE USED.
* RECOMMENDED PEAK TEMPERATURE FOR WIDEBODY 400mils PACKAGE IS 245 °C
8
All Avago data sheets report the creepage and clearance
inherent to the optocoupler component itself. These di-
mensions are needed as a starting point for the equip-
ment designer when determining the circuit insulation
requirements.
However, once mounted on a printed circuit board, mini-
mum creepage and clearance requirements must be
met as specied for individual equipment standards. For
Insulation and Safety Related Specications
Parameter Symbol
Value
Units Conditions
HCPL-
4504
HCPL-
J454
-400E/-600E
HCPL-J454
All other
options
HCPL-
0454
HCNW
4504
Minimum External
Air Gap
(External Clearance)
L(101) 7.1 8.0 7.4 4.9 9.6 mm Measured from input ter-
minals to output terminals,
shortest distance through air.
Minimum External
Tracking
(External Creepage)
L(102) 7.4 8.0 8.0 4.8 10.0 mm Measured from input ter-
minals to output terminals,
shortest distance path along
body.
Minimum Internal
Plastic Gap
(Internal Clearance)
0.08 0.5 0.5 0.08 1.0 mm Through insulation distance,
conductor to conductor,
usually the direct distance
between the photoemitter
and photodetector inside the
optocoupler cavity.
Minimum Internal
Tracking (Internal
Creepage)
NA NA NA NA 4.0 mm Measured from input ter-
minals to output terminals,
along internal cavity.
Tracking Resistance
(Comparative
Tracking Index)
CTI ≥175 ≥175 ≥175 ≥175 ≥200 Volts DIN IEC 112/VDE 0303 Part 1
Isolation Group IIIa IIIa IIIa IIIa IIIa Material Group (DIN VDE
0110, 1/89, Table 1)
creepage, the shortest distance path along the surface
of a printed circuit board between the solder llets of
the input and output leads must be considered. There
are recommended techniques such as grooves and ribs
which may be used on a printed circuit board to achieve
desired creepage and clearances. Creepage and clear-
ance distances will also change depending on factors
such as pollution degree and insulation level.
Regulatory Information
The devices contained in this data sheet have been approved by the following agencies:
Agency/Standard HCPL-4504 HCPL-J454 HCPL-0454 HCNW4504
Underwriters Laboratories (UL)
Recognized under UL1577,
Component Recognition Program,
Category FPQU2, File E55361
UL1577 3750 Vrms /
1 minute,
Option 020 5000
Vrms / 1 minute
3750 Vrms /
1 minute
3750 Vrms /
1 minute
5000 Vrms /
1 minute
Canadian Standards Association (CSA)
File CA88324
Component
Acceptance
Notice #5
3750 Vrms /
1 minute,
Option 020 5000
Vrms / 1 minute
3750 Vrms /
1 minute
3750 Vrms /
1 minute
5000 Vrms /
1 minute
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01
Option 060
V
IORM
= 630 Vpeak
V
IORM
= 891
Vpeak
Option 060
V
IORM
= 560
Vpeak
V
IORM
= 1414
Vpeak
9
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics
Description Symbol
HCPL-0454 HCPL-4504
HCPL-J454 HCNW4504 UnitOPTION 060 OPTION 060
Installation classication per
DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤150 V rms
for rated mains voltage ≤300 V rms
for rated mains voltage ≤450 V rms
for rated mains voltage ≤600 V rms
for rated mains voltage ≤1000 V rms
I-IV
I-III
I-IV
I-IV
I-III
I-IV
I-IV
I-III
I-III
I-IV
I-IV
I-IV
I-IV
I-III
Climatic Classication 55/100/21 55/100/21 55/100/21 55/85/21
Pollution Degree (DIN VDE 0110/1.89) 2 2 2 2
Maximum Working Insulation Voltage V
IORM
560 630 891 1414 V
peak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production
Test with t
m
= 1 sec,
Partial Discharge < 5 pC
V
PR
1050 1181 1670 2652 V
peak
Input to Output Test Voltage, Method a*
V
IORM
x 1.5 = V
PR
, Type and Sample
Test,
t
m
= 60 sec,
Partial Discharge < 5 pC
V
PR
840 945 1336 2121 V
peak
Highest Allowable Overvoltage*
(Transient Overvoltage, t
ini
= 10 sec)
Safety Limiting Values - Maximum
Values Allowed in the Event of a Failure,
also see Thermal Derating curve
V
IOTM
4000 6000 6000 8000 V
peak
Case Temperature T
S
150 175 175 150 °C
Input Current I
S,INPUT
150 230 400 400 mA
Output Power P
S,OUTPUT
600 600 600 700 mW
Insulation Resistance at T
S
,
V
IO
= 500 V
R
S
≥10
9
≥10
9
≥10
9
≥10
9
Ω
*Refer to the optocoupler section of the Designer's Catalog, under regulatory information (IEC/EN/DIN EN 60747-5-2) for a detailed description of
Method a and Method b partial discharge test proles.
NOTE: These optocouplers are suitable for "safe electrical isolation" only within the safety limit data. Maintenance of the safety data shall be ensured
by means of protective circuits.
NOTE: Insulation Characteristics are per IEC/EN/DIN EN 60747-5-2.
NOTE: Surface mount classication is Class A in accordance with CECC 00802.

HCPL-4504#060

Mfr. #:
Manufacturer:
Broadcom / Avago
Description:
High Speed Optocouplers 1MBd 1Ch 12mA
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS