WM1824 Production Data
w
PD, Rev 4.1, December 2011
4
PIN DESCRIPTION
PIN NO NAME TYPE DESCRIPTION
1 BCLK
Digital In Digital audio interface bit clock
2 MCLK
Digital In Master clock
3 DBVDD
Supply Digital Buffer Supply
4 NC
5 NC
6 LINEVDD
Supply Charge Pump supply
7 NC
8 NC
9 CPCA
Analogue Out Charge Pump fly back capacitor pin
10 LINEGND
Supply Charge Pump ground
11 CPCB
Analogue Out Charge Pump fly back capacitor pin
12 CPVOUTN
Analogue Out Charge Pump negative rail decoupling pin
13 LINEVOUTR
Analogue Out Right line output
14 NC
15 LINEVOUTL
Analogue Out Left line output
16 AGND
Supply Analogue ground
17 AVDD
Supply Analogue supply
18 VMID
Analogue Out Analogue midrail decoupling pin
19 MUTE ¯¯¯¯¯
Digital In
0 = Mute enabled
1 = Mute disabled
20 NC
21 NC
22 AIFMODE
Digital In
1 = 24-bit Left Justified
0 = 24-bit I
2
S
23 LRCLK
Digital In Digital audio interface left/right clock
24 DACDAT
Digital In Digital audio interface data input
Production Data WM1824
w
PD, Rev 4.1, December 2011
5
ABSOLUTE MAXIMUM RATINGS
Absolute Maximum Ratings are stress ratings only. Permanent damage to the device may be caused by continuously
operating at or beyond these limits. Device functional operating limits and guaranteed performance specifications are given
under Electrical Characteristics at the test conditions specified.
ESD Sensitive Device. This device is manufactured on a CMOS process. It is therefore generically
susceptible to damage from excessive static voltages. Proper ESD precautions must be taken during handling
and storage of this device.
Wolfson tests its package types according to IPC/JEDEC J-STD-020B for Moisture Sensitivity to determine acceptable storage
conditions prior to surface mount assembly. These levels are:
MSL1 = unlimited floor life at <30C / 85% Relative Humidity. Not normally stored in moisture barrier bag.
MSL2 = out of bag storage for 1 year at <30C / 60% Relative Humidity. Supplied in moisture barrier bag.
MSL3 = out of bag storage for 168 hours at <30C / 60% Relative Humidity. Supplied in moisture barrier bag.
The Moisture Sensitivity Level for each package type is specified in Ordering Information.
CONDITION MIN MAX
AVDD, LINEVDD, DBVDD
-0.3V +4.5V
Voltage range digital inputs
LINEGND -0.3V LINEVDD +0.3V
Voltage range analogue inputs
AGND -0.3V AVDD +0.3V
Temperature range, T
A
-40°C +125°C
Storage temperature after soldering
-65°C +150°C
Notes
1. Analogue grounds must always be within 0.3V of each other.
2. LINEVDD and AVDD must always be within 0.3V of each other.
RECOMMENDED OPERATING CONDITIONS
PARAMETER SYMBOL TEST CONDITIONS MIN TYP MAX UNIT
Analogue supply range
AVDD, LINEVDD 2.97 3.3 3.63 V
Ground
AGND, LINEGND 0 V
Digital Buffer supply range
DBVDD 1.62 3.63 V
WM1824 Production Data
w
PD, Rev 4.1, December 2011
6
ELECTRICAL CHARACTERISTICS
Test Conditions
LINEVDD=AVDD=DBVDD=3.3V, LINEGND=AGND=0V, T
A
=+25
°
C, fs=48kHz, MCLK=256fs, 24-bit data, unless otherwise stated.
PARAMETER SYMBOL TEST CONDITIONS MIN TYP MAX UNIT
Analogue Output Levels
Output Level
0dBFS 2.04 2.1×AVDD
3.3¯¯¯¯¯¯¯¯
2.14 Vrms
Load Impedance
1
A
k
Load Capacitance
No external RC filter 300 pF
With filter shown in
Figure 15
1 µF
DAC Performance
Signal to Noise Ratio
SNR
R
L
= 10k
A-weighted
106 dB
R
L
= 10k
Un-weighted
104 dB
Dynamic Range
DNR
R
L
= 10k
A-weighted
104 dB
Total Harmonic Distortion THD
-1dBFS -89 dB
0dBFS -86 dB
AVDD + LINEVDD
Power Supply Rejection Ratio
PSRR
100Hz 54 dB
1kHz 54 dB
20kHz 50 dB
Channel Separation
1kHz
100
dB
20Hz to 20kHz
95
dB
System Absolute Phase
0 degrees
Channel Level Matching
0.1 dB
Mute Attenuation
-120 dB
DC Offset at LINEVOUTL and
LINEVOUTR
-1 0 1 mV
Digital Logic Levels
Input HIGH Level
V
IH
0.7
LINEVDD
V
Input LOW Level V
IL
0.3
LINEVDD
V
Input Capacitance 10 pF
Input Leakage -0.9 0.9 A
Note:
1. To prevent over-current protection shutdown of the device, ensure that the load impedance is never less than 100. If
a load impedance of less than 100 is presented to either LINEVOUTL or LINEVOUTR, the device may go into a
protective shutdown state where the charge pump will stop running and the device will shut down. It will take a
hardware reset to come out of this state (recycle the power supplies or hold /MUTE low for 1024 LRCLK cycles after
the low impedance load condition has been removed).
TERMINOLOGY
1. Signal-to-Noise Ratio (dB) – SNR is a measure of the difference in level between the maximum theoretical full scale
output signal and the output with no input signal applied.
2. Total Harmonic Distortion (dB) – THD is the level of the rms value of the sum of harmonic distortion products relative to
the amplitude of the measured output signal.
3. All performance measurements carried out with 20kHz low pass filter, and where noted an A-weighted filter. Failure to
use such a filter will result in higher THD and lower SNR readings than are found in the Electrical Characteristics. The
low pass filter removes out of band noise; although it is not audible it may affect dynamic specification values.
4. Mute Attenuation – This is a measure of the difference in level between the full scale output signal and the output with
mute applied.

WM1824CGEFL/V

Mfr. #:
Manufacturer:
Cirrus Logic
Description:
Audio D/A Converter ICs Stereo DAC w/ 2Vrms ground ref line Dvr
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union