Si3452/3
22 Rev. 0.47
Table 20. Si3452/3 Detect Encoding
Value Condition
000b Unknown
001b Short
010b Reserved
011b Rlow
100b Good
101b Rhigh
110b Ropen
111b Reserved
Table 21. Si3452/3 Class Encoding
Value Condition
000b Unknown
001b Class 1
010b Class 2
011b Class 3
100b Class 4
101b Probes Not Equal
110b Class 0
111b Class Overload
Table 22. Si3452/3 Port Mode Encoding
Value Condition
00b Shutdown
01b Manual
10b Semiauto
11b Auto
Si3452/3
Rev. 0.47 23
Table 23. Si3452/3 Port Configuration
PoE+ bit Class Auto Mode Setting of
I
CUT
Register
I
CUT
Nominal Ilim Nominal*
0 or 1 don’t care 1 0x1E 97 mA 425 mA
0 or 1 don’t care 2 0x35 170 mA 425 mA
0 or 1 don’t care 0/3 0x75 375 mA 425 mA
0 4 0x75 375 mA 425 mA
1 4 0xC9 640 mA 850 mA
*Note: During initial port turn-on (T
START
time of 60 msec), the current limit is set to 425 mA, even in PoE+ mode.
Table 24. Si3452/3 Command Codes
Command CMD Register [B5..B2]
[B1..B0] Command
Parameter
2 Byte Return Value
Power on port 0x04 | port no 0001b 2 bit port number
1
Power off port 0x08 | port no 0010b 2 bit port number
Reset port 0x0C | port no 0011b 2 bit port number
Toggle detection
back-off timing
2
0x10 0100b NA
Reset chip 0x14 0101b NA
Get V
EE
0x18 0110b NA V
EE
in mV units
Read port current
0x1C | port no 0111b 2 bit port number
Port current in 100 µA
units
Shut down
low-priority ports
0x20 1000b NA
Notes:
1.
Port 1 has 2 bit port number 0x00; port 2 is 0x01, etc.
2. This command toggles bit 0 of Register 0x1D. When bit zero is set, the detection back-off of 2 seconds is implemented
(alternative B or “midspan” mode).
Si3452/3
24 Rev. 0.47
6. Operational Notes
6.1. Port Turn On
If the port is turned on by putting it in auto mode, the Si3452/3 will take care of all specified timing, and it will take
care of the two-event classification if the first event result is Class 4 and PoE+ mode is enabled. However, if
automatic mode operation is not desired after port turn-on, the port should be set to semi-auto or manual mode
once it has powered. In automatic mode, I
CUT
is set according to the classification result.
The port turn-on command is used to turn on a port in semi-auto or manual mode. If the port is turned on in semi-
auto mode, turn-on is delayed until the next detection and classification. If the detection or classification result is
not valid, the port will not power. If the classification is Class 4 and PoE+ mode is enabled, a 2-event classification
is given. I
CUT
setting is not automatic for port turn-on in semi-auto or manual mode.
If the port is turned on by putting it in manual mode, the normal sequence is to start with the port in semi-auto mode
and interrupt on a classification complete, which indicates that there is a valid PD signature and that a classification
result is available. Based on the classification result, the host can make a decision to apply power or not. The IEEE
standard requires that a port be powered within 400 msec of a valid detect complete. It is also desirable to power
the port prior to the start of the next detection pulse, which can occur in as little as 300 msec. Therefore, it is
recommended that ports be powered in under 250 msec from the class complete interrupt when using the manual
mode turn-on command.
Using manual mode turn-on, detection is not done prior to port turn on, but classification is always performed just
prior to port turn on. Ports are turned on in manual mode regardless of the classification result. 2-event
classification is performed if the first event result is Class 4 and the port is enabled for PoE+ mode. The manual
mode classification step does not generate a classification complete flag because it is assumed that the
classification was already done in semi-auto mode and the host has already made the decision to grant power.
During the initial 60 msec (Tstart) time of port turn-on, 1x current limit and I
CUT
= 375 mA (nominal) is enforced.
After Tstart, if the port is not overloaded, Pgood is set to true, and I
CUT
and 1x or 2x current limit will follow the I
2
C
register settings. In auto mode, the I
2
C registers are set according to the classification result, but, if desired, they
can be overwritten after Pgood becomes true. After Tstart, 2x current limit is always allowed if PoE+ mode is
enabled.
6.2. Changing the Interrupt Mask
The INT register and INT pin are always synchronized. However, there can be up to a 5 msec delay between an
event that causes or clears an interrupt and the update of the register and pin.
Thus, if the INT mask register is changed to clear an interrupt or to block an interrupt source, there can be up to a
5 msec delay between the change of the INT mask register and the resultant change in the INT register and INT
pin.
Generally, use of the mask register to clear interrupts is not recommended; it is better to clear an interrupt by
reading the appropriate COR register.
6.3. Port Voltage and Current Measurements
Port current voltage and current are reported as of the time the measurement command is written to register 0x12.
Spikes of current or other momentary current changes are not filtered. It may be desireable to add a ~1 second
averaging filter to reported current when using port current information for power management decisions.

SI3452-B01-GM

Mfr. #:
Manufacturer:
Silicon Labs
Description:
Hot Swap Voltage Controllers Quad PoE/PoE+ PSE port controller (dV/dt disconnect)
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union