8 www.clare.com Rev. B
Preliminary
1.7 Thermal Shutdown Characteristics
1.8 Protection Circuitry Electrical Specifications
Parameter Conditions Symbol Minimum Typical Maximum Unit
Activation Temperature
T
SD
=> Low
T 110 125 150 °C
Hysteresis
T
SD
=> High
∆T10 - 25°C
Parameter Conditions Symbol Minimum Typical Maximum Unit
Parameters Related to the Diodes in the Diode Bridge
Voltage drop at continuous
current (50/60 Hz)
Apply ± dc current limit of break switches
V
F
-2.13
V
Voltage drop at surge
current
Apply ± dynamic current limit of break
switches
V
F
-5-
Parameters Related to the Protection SCR
Surge current - - - - * A
Trigger current
+25°C
I
TRIG
-
60
-mA
+85°C 35
Hold current
+25°C
I
HOLD
- 100
-mA
+85°C 60 70
Gate trigger voltage
I
GATE
= I
Tr i g g e r
**
V
TBAT
or
V
RBAT
V
BAT
-4
-
V
BAT
-2
V
Reverse leakage current
V
BAT
= -48V I
VBAT
--1.0µA
On-state voltage
0.5 A, t = 0.5 ms V
TBAT
or
V
RBAT
-
-3
-V
2.0 A, t = 0.5 ms -5
*Passes GR1089 and ITU-T K.20 with appropriate protection in place.
** V
BAT
must be capable of sourcing I
TRIGGER
for the internal SCR to activate.