SiT3373
220 MHz to 725 MHz Ultra-low Jitter Differential VCXO
Rev 1.03
Page 15 of 16 www.sitime.com
Table 11. APR Table
Absolute pull range (APR) = Nominal pull range (PR) - frequency stability (F_stab) - aging
[16]
Nominal Pull Range
Frequency Stability
± 15 ± 25 ± 35 ±50
APR (ppm)
± 25 ± 5
—
— —
± 50 ± 30 ± 20 ± 10
—
± 80 ± 60 ± 50 ± 40 ± 25
± 100 ± 80 ± 70 ± 60 ± 45
± 150 ± 130 ± 120 ± 110 ± 95
± 200 ± 180 ± 170 ± 160 ± 145
± 400 ± 380 ± 370 ± 360 ± 345
± 800 ± 780 ± 770 ± 760 ± 745
± 1600 ± 1580 ± 1570 ± 1560 ± 1545
± 3200 ± 3180 ± 3170 ± 3160 ± 3145
Note:
16. Aging includes solder down shift and 20-year aging.
Table 12. Additional Information
Document Description Download Link
ECCN #: EAR99
Five character designation used on the
commerce Control List (CCL) to identify dual
use items for export control purposes.
—
Part number Generator Tool used to create the part number based on
desired features.
—
Manufacturing Notes Tape & Reel dimension, reflow profile and
other manufacturing related info
http://www.sitime.com/manufacturing-notes
Qualification Reports RoHS report, reliability reports,
composition reports
http://www.sitime.com/support/quality-and-reliability
Performance Reports Additional performance data such as phase
noise, current consumption and jitter for
selected frequencies
http://www.sitime.com/support/performance-measurement-report
Termination Techniques
Termination design recommendations http://www.sitime.com/support/application-notes
Layout Techniques
Layout recommendations http://www.sitime.com/support/application-notes