Figure 1. Simplifi ed Schematic
–VIN
(1)
+V
IN
(4)
CASE
(2)
REMOTE*
ON/OFF
CONTROL
(3)
PMW
CONTROLLER
OPTO
ISOLATION
REFERENCE &
ERROR MAP
SWITCH
CONTROL
INPUT UNDERVOLTAGE, INPUT
OVERVOLTAGE, AND OUTPUT
OVERVOLTAGE COMPARATORS
+V
OUT
(5)
–V
OUT
(9)
V
OUT
TRIM
(7)
+SENSE
(6)
–SENSE
(8)
Typical topology is shown.
*Can be ordered with positive (standard)
or negative (optional) polarity.
Typical Unit
FEATURES
Standard “half-brick” confi guration
Certifi ed to UL-60950-1, CSA-C22.2 No.
60950-1, IEC\EN 60950-1, 2nd edition
(some models pending)
Fully isolated, 2250Vdc guaranteed
Output voltages: 1.8 – 15 Volts
VIN range: 36-75V or 18-36V
Full 50-150 Watt output power
Reliable SMT-on-pcb construction
Input under and output overvoltage shutdown
Output current limiting and short-circuit
protection
On/off, VOUT trim and sense functions
Modifi cations and customs for OEMs
RoHS-6 construction/attach
The high effi ciency, low noise and long-term reli-
ability that defi nes Murata Power Solutions’ DC/
DC Converters now comes to you in the standard
“half-brick” confi guration (2.3˝ x 2.4˝ x 0.40˝).
Our new UCH Series is certifi ed to UL/EN60950-
1 safety requirements (some models pending),
including each European country’s deviations. All
models have BASIC insulation; guarantee 2250Vdc
(in to out) isolation; and because they are designed
with Class B thermal insulation, satisfy all safety
requirements over their full operating tempera-
tures. Construction/attach meets stringent RoHS-6
specifi cations.
UCH Models are designed for demanding tele-
com, datacom and networking applications. Their
“semi-synchronous-rectifi er” design achieves
impressive effi ciencies. Output voltages are
1.8to15 Volts. The input voltage range is 36 to 75
or 18 to 36 Volts. All models meet the Low Voltage
Directive (LVD).
For high reliability and affordability, Murata
Power Solutions utilizes high-speed automatic
assembly to construct the UCH’s proven SMT-
on-pcb designs. An optional baseplate offers full
output power at maximum temperature.
UCH’s feature input fi lters, input undervoltage
and overvoltage lockout, output current limiting,
short-circuit protection, and thermal shutdown.
Additionally, all devices have output trim capability
and an on/off control pin that can be ordered with
either logic type.
PRODUCT OVERVIEW
n to o
with Cl
PR
REG.-Nr. C457
(some models pending
certifi cation)
NOT RECOMMENDED
FOR NEW DESIGNS
LAST TIME BUY: AUGUST 31, 2014. CLICK HERE FOR OBSOLESCENCE NOTICE OF FEBRUARY 2014.
www.murata-ps.com
www.murata-ps.com/support
For full details go to
www.murata-ps.com/rohs
Single Output UCH Models
Isolated, “Half-Brick”
1.8−15V Output DC/DC Converters
MDC_UCH Models.C01 Page 1 of 18