Output Current (Amps)
Ambient Temperature (
°
C)
400 lfm
200 lfm
300 lfm
100 lfm
30 40 50 60 70
20
24
8
16
12
32
40
28
36
UCH-3.3/35-D24 Maximum Current Temperature Derating (at sea level)
No baseplate, VIN = 24V, transverse airflow
V
IN
= 24V
V
IN
= 18V
Efficiency (%)
Load Current (Amps)
V
IN
= 36V
75
70
85
80
90
63 9 12 15 18 21 27 3024 33
95
Power Dissipation
(V
IN
= 24V)
UCH-3.3/35-D24 Efficiency and Power Dissipation
vs Line Voltage and Load Current @25˚C
Power Dissipation (Watts)
16
20
18
14
0
2
6
10
4
8
12
Output Current (Amps)
Ambient Temperature (
°
C)
200 lfm
300 lfm
100 lfm
30 40 50 60 8070
26
27
25
24
23
29
31
28
30
UCH-3.3/30-D48 Maximum Current Temperature Derating (at sea level)
No baseplate, V
IN = 48V, transverse airflow
Efficiency (%)
Load Current (Amps)
75
65
70
60
85
80
90
63 9 12 15 18 21 27 3024
95
Power Dissipation
(V
IN
= 48V)
V
IN
= 36V
V
IN
= 48V
V
IN
= 75V
UCH-3.3/30-D48 Efficiency and Power Dissipation
vs Line Voltage and Load Current @25˚C
Power Dissipation (Watts)
0
1
3
5
2
4
6
8
10
7
9
Efficiency (%)
Load Current (Amps)
V
IN
= 75V
75
85
80
90
4356789 11 1210 13 1514
95
Power Dissipation
(V
IN
= 48V)
70
65
55
60
V
IN
= 48V
V
IN
= 36V
UCH-3.3/15-D48 Efficiency and Power Dissipation
vs Line Voltage and Load Current @25˚C
Power Dissipation (Watts)
2
3
4
5
6
7
8
9
10
TYPICAL PERFORMANCE DATA
www.murata-ps.com/support
Single Output UCH Models
Isolated, “Half-Brick”
1.8−15V Output DC/DC Converters
MDC_UCH Models.C01 Page 10 of 18
Output Current (Amps)
Ambient Temperature (
°
C)
400 lfm200 lfm
30 40 50 60 70 80
14
16
12
10
20
18
300 lfm
100 lfm
UCH-5/20-D24 Maximum Current Temperature Derating (at sea level)
No baseplate, V
IN = 24V, transverse airflow
V
IN
= 24V
V
IN
= 18V
Efficiency (%)
Load Current (Amps)
V
IN
= 36V
75
70
85
80
90
63 9 12 15 18
95
Power Dissipation
(V
IN
= 24V)
UCH-5/20-D24 Efficiency and Power Dissipation
vs Line Voltage and Load Current @25˚C
Power Dissipation (Watts)
20
0
2
6
10
4
8
12
16
14
18
Output Current (Amps)
Ambient Temperature (
°
C)
400 lfm200 lfm
30 40 50 60 70 80
18
22
14
10
30
26
300 lfm
100 lfm
UCH-5/30-D48 Maximum Current Temperature Derating (at sea level)
No baseplate, VIN = 48V, transverse airflow
Efficiency (%)
Load Current (Amps)
75
70
85
80
90
63 9 12 1815 24 2721 30
95
V
IN
= 48V
V
IN
= 75V
V
IN
= 36V
Power Dissipation
(V
IN
= 48V)
UCH-5/30-D48 Efficiency and Power Dissipation
vs Line Voltage and Load Current @25˚C
Power Dissipation (Watts)
0
4
8
12
16
20
30 40 50 60 70 80 85
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
UCH-12/4.2-D48 Maximum Current Temperature Derating at sea level
(VIN = 48V, airflow direction from VIN to VOUT, no baseplate)
Output Current (Amps)
Ambient Temperature (
°
C)
Natural Convection
0.42 0.84 1.26 1.68 2.1 2.52 2.94 3.36 3.78 4.2
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
65
67
69
71
73
75
77
79
81
83
85
87
89
91
93
UCH-12/4.2-D48 Efficiency and Power Dissipation
vs Line Voltage and Load Current @25˚C
Power Dissipation (Watts)
Efficiency (%)
Load Current (Amps)
V
IN
= 75V
V
IN
= 36V V
IN
= 48V
Power Dissipation
(V
IN
= 48V)
TYPICAL PERFORMANCE DATA
www.murata-ps.com/support
Single Output UCH Models
Isolated, “Half-Brick”
1.8−15V Output DC/DC Converters
MDC_UCH Models.C01 Page 11 of 18
Efficiency (%)
Load Current (Amps)
75
65
70
85
80
90
23455.54.53.52.51.51 66.5
100
95
Power Dissipation
(V
IN
= 48V)
V
IN
= 48V
V
IN
= 75V
V
IN
= 36V
UCH-15/6.7-D48 Efficiency and Power Dissipation
vs Line Voltage and Load Current @25˚C
Power Dissipation (Watts)
0
4
2
6
10
14
8
12
Output Current (Amps)
Ambient Temperature (
°
C)
400 lfm200 lfm
30 40 50 60 70 80
4
5
2
3
1
0
7
6
300 lfm
100 lfm
UCH-15/6.7-D48 Maximum Current Temperature Derating (at sea level)
No baseplate, VIN = 48V, transverse airflow
Output Current (Amps)
Ambient Temperature (
°
C)
400 lfm200 lfm
30 40 50 60 70 80
12.5
11.5
19.5
9.5
8.5
7.5
6.5
300 lfm
100 lfm
UCH-12/12.5-D48 Maximum Current Temperature Derating (at sea level)
No baseplate, VIN = 48V, transverse airflow
Efficiency (%)
Load Current (Amps)
75
70
85
80
90
5643789 10 11 12
95
65
Power Dissipation
(V
IN
= 48V)
V
IN
= 75V
V
IN
= 48VV
IN
= 36V
UCH-12/12.5-D48 Efficiency and Power Dissipation
vs Line Voltage and Load Current @25˚C
Power Dissipation (Watts)
6
10
4
8
12
16
20
14
18
TYPICAL PERFORMANCE DATA
www.murata-ps.com/support
Single Output UCH Models
Isolated, “Half-Brick”
1.8−15V Output DC/DC Converters
MDC_UCH Models.C01 Page 12 of 18

UCH-3.3/35-D24PB-C

Mfr. #:
Manufacturer:
Description:
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union