NCN5110
www.onsemi.com
9
Table 4. DC PARAMETERS The DC parameters are given for a device operating within the Recommended Operating Conditions
unless otherwise specified. Convention: currents flowing in the circuit are defined as positive.
Symbol UnitMaxTypMinRemark/Test ConditionsParameterPin(s)
FAN−IN CONTROL
I
pu,fanin
FANIN Pull−Up Current FANIN−pin
FANIN shorted to GND,
Pull−up connected to V
AUX
10 20 40
mA
DIGITAL INPUTS
V
IL
nV20VEN,
nDC2EN,
RXD, XCLKC
Logic Low Threshold 0 0.7 V
V
IH
Logic High Threshold 2.65 V
DDD
V
R
DOWN
XCLKC Internal Pull−Down Resistor 5 10 28
kW
DIGITAL OUTPUTS
V
OL
TXD, XCLK
Logic low output level 0 0.4 V
V
OH
Logic high output level
V
DDD
−
0.45
V
DDD
V
I
L
XCLK
Load Current
8 mA
TXD 4 mA
V
OL
SAVEB,
RESETB
Logic low level open drain I
OL
= 4 mA 0.4 V
R
up
Internal Pull−up Resistor 20 40 80
kW
TEMPERATURE MONITOR
T
TW
Thermal Warning
Rising temperature
See Figure 8
105 115 125 °C
T
TSD
Thermal shutdown
Rising temperature
See Figure 8
130 140 150 °C
T
Hyst
Thermal Hysteresis See Figure 8 5 11 15 °C
DT
Delta T
TSD
and T
TW
See Figure 8 21.7 °C
PACKAGE THERMAL RESISTANCE VALUE
R
q
,
ja
Thermal Resistance
Junction−to−Ambient
Simulated Conform
JEDEC JESD−51, (2S2P)
30 K/W
Simulated Conform
JEDEC JESD−51, (1S0P)
60 K/W
R
q
,
jp
Thermal Resistance
Junction−to−Exposed Pad
0.95 K/W
Table 5. AC PARAMETERS The AC parameters are given for a device operating within the Recommended Operating Conditions
unless otherwise specified.
Symbol
Pin(s) Parameter Remark/Test Conditions Min Typ Max Unit
POWER SUPPLY
t
BUS_FILTER
VBUS1 VBUS1 filter time See Figure 4 2 ms
FIXED DC−DC CONVERTER
t
VSW1_rise
VSW1
Rising slope at VSW1−pin 0.45 V/ns
t
VSW1_fall
Falling slope at VSW1−pin 0.6 V/ns
ADJUSTABLE DC−DC CONVERTER
t
VSW2_rise
VSW2
Rising slope at VSW2−pin 0.45 V/ns
t
VSW2_fall
Falling slope at VSW2−pin 0.6 V/ns
XTAL OSCILLATOR
f
XTAL
XTAL1, XTAL2 XTAL Oscillator Frequency 16 MHz
Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product
performance may not be indicated by the Electrical Characteristics if operated under different conditions.