BATTERY PROTECTION IC FOR 1-CELL PACK
Rev.5.3_00
S-8261 Series
Seiko Instruments Inc.
25
Precautions
The application conditions for the input voltage, output voltage, and load current should not exceed the package power
dissipation.
Do not apply an electrostatic discharge to this IC that exceeds the performance ratings of the built-in electrostatic
protection circuit.
SII claims no responsibility for any and all disputes arising out of or in connection with any infringement by products
including this IC of patents owned by a third party.
BATTERY PROTECTION IC FOR 1-CELL PACK
S-8261 Series
Rev.5.3_00
Seiko Instruments Inc.
26
Characteristics (Typical Data)
1. Detection / Release Voltage Temperature Characteristics
Overcharge detection voltage vs. temperature Overcharge release voltage vs. temperature
4.34
4.36
4.38
4.40
4.42
4.44
25 0 25 50 75
Ta [°C]
V
CU
[V]
50 100
3.92
3.94
3.96
3.98
4.00
4.02
25 0 25 50 75
Ta
[
°C
]
V
CL
[V]
50 100
Overdischarge detection voltage vs. temperature Overdischarge release voltage vs. temperature
2.94
2.96
2.98
3.00
3.02
3.04
25 0 25 50 75
Ta [°C]
V
DL
[V]
50 100
3.34
3.36
3.38
3.40
3.42
3.44
25 0 25 50 75
Ta [°C]
V
DU
[V]
50 100
Overcurrent 1 detection voltage vs. temperature Overcurrent 2 detection voltage vs. temperature
0.15
0.20
0.25
0.30
0.35
0.40
0.45
25 0 25 50 75
Ta [°C]
V
IOV1
[V]
50 100
0.40
0.45
0.50
0.55
0.60
0.65
25 0 25 50 75
Ta [°C]
V
IOV2
[V]
50 100
Load short-circuiting detection voltage vs. temperature
1.0
1.1
1.2
1.3
1.4
1.5
25 0 25 50 75
Ta [°C]
V
SHORT
[V]
50 100
BATTERY PROTECTION IC FOR 1-CELL PACK
Rev.5.3_00
S-8261 Series
Seiko Instruments Inc.
27
2. Current Consumption Temperature Characteristics
Current consumption vs. temperature in normal mode Current consumption vs. temperature in power-down mode
0
1
2
3
4
5
25 0 25 50 75
Ta
[
°C
]
I
OPE
[
μ
A]
50 100
0
0.02
0.04
0.06
0.08
0.10
25 0 25 50 75
Ta [°C]
I
PDN
[
μ
A]
50 100
3. Current Consumption Power Voltage Characteristics (Ta = 25°C)
Current consumption vs. power supply voltage dependency
0
1
2
3
4
5
6
0 2 4 6 8 10 12
V
DD
[V]
I
OPE
[μA]
4. Detection / Release Delay Time Temperature Characteristics
Overcharge detection delay time vs. temperature Overcharge release delay time vs. temperature
0.50
0.75
1.00
1.25
1.50
25 0 25 50 75
Ta [°C]
t
CU
[s]
50 100
10
20
30
40
50
60
25 0 25 50 75
Ta [°C]
t
CL
[ms]
50 100
Overdischarge detection delay time vs. temperature
100
120
140
160
180
200
25 0 25 50 75
Ta [°C]
t
DL
[ms]
50 100

S-8261ABJMD-G3JT2G

Mfr. #:
Manufacturer:
ABLIC
Description:
Battery Management Lithium-Ion battery protection (1 cell)
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union