Electrical specifications VND5004CSP30
10/28 DocID027938 Rev 3
Note: To ensure long term reliability under heavy overload or short-circuit conditions, protection
and related diagnostic signals must be used together with a proper software strategy. If the
device is subjected to abnormal conditions, this software must limit the duration and number
of activation cycles.
Table 7. Logic input
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
IL1,2
Input low level voltage 0.9 V
I
IL1,2
Low level input current V
IN
=0.9V 1 μA
V
IH1,2
Input high level voltage 2.1 V
I
IH1,2
High level input current V
IN
=2.1V 10 μA
V
I(hyst)1,2
Input hysteresis voltage 0.25 V
V
ICL1,2
Input clamp voltage
I
IN
= 1 mA 5.5 7 V
I
IN
= -1 mA -0.7 V
V
CSDL
CS_DIS low level voltage 0.9 V
I
CSDL
Low level CS_DIS current V
CSD
= 0.9 V 1 μA
V
CSDH
CS_DIS high level voltage 2.1 V
I
CSDH
High level CS_DIS current V
CSD
= 2.1 V 10 μA
V
CSD(hyst)
CS_DIS hysteresis voltage 0.25 V
V
CSCL
CS_DIS clamp voltage
I
CSD
= 1 mA 5.5 7 V
I
CSD
= -1 mA -0.7 V
Table 8. Protection and diagnostics
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
limH
Short circuit current
V
CC
= 13 V 70 100 140 A
5 V < V
CC
< 24 V 140 A
I
limL
Short circuit current
during thermal cycling
V
CC
= 13 V; T
R
< T
j
< T
TSD
40 A
T
TSD
Shutdown temperature 150 175 200 °C
T
R
Reset temperature T
RS
+1 T
RS
+5 °C
T
RS
Thermal reset of
STATUS
135 °C
T
HYST
Thermal hysteresis
(T
TSD
-T
R
)
7°C
V
DEMAG
Turn-off output voltage
clamp
I
OUT
= 2 A; V
IN
= 0;
L = 6 mH
V
CC
-27 V
CC
-30 V
CC
-33 V