TLP291
2014-09-22
10
EN 60747-5-5 Option:(V4)
Types : TLP291
Type designations for “option: (V4)”, which are tested under EN 60747 requirements.
(e.g.): TLP291 (V4GB-TP,E V4 : EN 60747 option
GB : CTR rank type
TP : Standard tape & reel type
E : `G`/RoHS COMPATIBLE (Note4 )
Note: Use TOSHIBA standard type number for safety standard application.
(e.g.): TLP291(V4GB-TP,E TLP291
Note4: Please contact your Toshiba sales representative for details on environmental information such
as the product’s RoHS compatibility.
RoHS is the Directive 2002/95/EC of the European Parliament and of the Council of 27
January 2003 on the restriction of the use of certain hazardous substances in electrical and
electronics equipment.
EN 60747 Isolation Characteristics
Description Symbol Rating Unit
Application classification
for rated mains voltage 150Vrms
for rated mains voltage 300Vrms
I-IV
I-III
-
Climatic classification
55 / 110 / 21 -
Pollution degree
2 -
Maximum operating insulation voltage V
IORM
707 Vpk
Input to output test voltage, Method A
Vpr=1.5 × V
IORM
, type and sample test
tp=10s, partial discharge<5pC
V
pr
1060 Vpk
Input to output test voltage, Method B
Vpr=1.875 × V
IORM
, 100% production test
tp=1s, partial discharge<5pC
V
pr
1325 Vpk
Highest permissible overvoltage
(transient overvoltage, tpr=60s)
V
TR
6000 Vpk
Safety limiting values (max. permissible ratings in case of fault,
also refer to thermal derating curve)
current (input current: I
F
, Psi=0mW)
power (output or total power dissipation)
temperature
I
si
P
si
T
si
250
400
150
mA
mW
°C
Insulation resistance
V
IO
=500V, Ta=T
si
R
si
>
=
10
9
TLP291
2014-09-22
11
Insulation Related Specifications
Minimum creepage distance Cr 5.0mm
Minimum clearance Cl 5.0mm
Minimum insulation thickness ti 0.4mm
Comparative tracking index CTl 175
1. If a printed circuit is incorporated, the creepage distance and clearance may be reduced below this value.
(e.g. at a standard distance between soldering eye centers of 3.5mm).
If this is not permissible, the user shall take suitable measures.
2. This photocoupler is suitable for ‘safe electrical isolation’ only within the safety limit data.
Maintenance of the safety data shall be ensured by means of protective circuit.
VDE test sign: Marking on product
for EN 60747
: Marking on packing
for EN 60747
Marking Example: TLP291
V
V
D
E
1pin mark
CTR rank mark
Lot No.
Type
Country of origin
e.g.) J; Japan
Option(V4) mark
Process Lot No.
TLP291
2014-09-22
12
Figure
1 Partial discharge measurement procedure according to EN 60747
Destructive test for qualification and sampling tests.
Method A
(for type and sampling tests,
destructive tests)
t
1,
t
2
t
3,
t
4
t
p
(Measuring time for
partial discharge)
t
b
t
ini
V
V
INITIAL
(6kV)
V
pr
(1060V)
V
IORM
(707V)
0
t
1
t
ini
t
3
t
2
t
P
t
b
t
4
t
= 1 to 10 s
= 1 s
= 10 s
= 12 s
= 60 s
t
P
V
pr
(1325V )
V
IORM
(707V )
V
t
t
3
t
4
t
b
Figure
2 Partial discharge measurement procedure according to EN 60747
Non-destructive test for100% inspection.
Method B
(for sample test, non-
destructive test)
t
3
, t
4
t
p
(Measuring time for
partial discharge)
t
b
= 0.1 s
= 1 s
= 1.2 s
Figure
3 Dependency of maximum safety ratings on ambient temperature
500
400
300
200
100
0
0 25 50 75 100 125 150 175
500
400
300
200
100
0
Ta (°C)
Psi
Isi
Isi
(mA)
Psi
(
mW
)

TLP291(E)

Mfr. #:
Manufacturer:
Toshiba
Description:
Transistor Output Optocouplers Photocoupler 80V 50mA 3750Vrms
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union