Data Sheet ADG936/ADG936-R
Rev. B | Page 7 of 16
TYPICAL PERFORMANCE CHARACTERISTICS
04503-015
FREQUENCY (Hz)
10G10k 100k 1M 10M 100M 1G
INSERTION LOSS (dB)
–
0.3
–0.4
–0.5
–
0.6
–0.7
–0.8
–0.9
–1.0
–1.1
–
1.2
–1.3
–1.4
–
1.5
–1.6
–1.7
–1.8
–1.9
–2.0
–
2.1
–2.2
–2.3
–2.4
–2.5
–2.6
–2.7
–2.8
–2.9
–
3.0
V
DD
= 2.25V
V
DD
= 2.50V
V
DD
= 2.75V
Figure 7. Insertion Loss vs. Frequency over Supplies
(S12 and S21)
04503-016
FREQUENCY (Hz)
10G10k 100k 1M 10M 100M 1G
INSERTION LOSS (dB)
–0.3
–0.5
–0.4
–0.6
–0.7
–0.8
–0.9
–1.0
V
DD
= 2.25V
V
DD
= 2.50V
V
DD
= 2.75V
Figure 8. Insertion Loss vs. Frequency over Supplies
(S12 and S21) (Zoomed Figure 7)
FREQUENCY (Hz)
10G10k 100k 1M 10M 100M 1G
INSERTION LOSS (dB)
–0.3
–0.8
–0.7
–0.6
–0.5
–0.4
–1.2
–1.1
–1.0
–0.9
–1.7
–2.2
–2.1
–2.0
–1.9
–1.8
–1.6
–1.5
–1.4
–1.3
–2.3
–2.4
–2.5
–2.6
–2.7
–2.9
–2.8
–3.0
V
DD
= 1.65V
V
DD
= 1.80V
V
DD
= 1.95V
Figure 9. Insertion Loss vs. Frequency over Supplies
(S12 and S21)
04503-018
FREQUENCY (Hz)
10G
10k 100k 1M 10M 100M 1G
INSERTION LOSS (dB)
–
0.3
–0.8
–0.7
–
0.6
–0.5
–
0.4
–
1.2
–1.1
–
1.0
–
0.9
–1.7
–
2.2
–2.1
–2.0
–
1.9
–1.8
–1.6
–
1.5
–1.4
–
1.3
–2.3
–2.4
–
2.5
–2.6
–2.7
–2.9
–2.8
–3.0
V
DD
= 2.5V
T
A
= –
40
°C
T
A
= +25°C
T
A
= +85°C
Figure 10. Insertion Loss vs. Frequency over Temperature
(S12 and S21)
04503-019
FREQUENCY (Hz)
10G10k 100k 1M 10M 100M 1G
OFF ISOLATION (dB)
–10
–20
–30
–40
–50
–60
–70
–80
S12
S21
V
DD
= 1.65V TO 2.75V
T
A
= 25°C
Figure 11. Isolation vs. Frequency over Supplies
04503-020
FREQUENCY (Hz)
10G1G10k 100k 1M 10M 100M
OFF ISOLATION (dB)
–10
–30
–20
–50
–40
–70
–60
–90
–80
–100
–110
T
A
= –40°C
T
A
= +85°C
T
A
= +25°C
V
DD
= 2.5V
Figure 12. Isolation vs. Frequency over Temperature