Nexperia
74AVC1T1004
1-to-4 fan-out buffer
Table 13. Dynamic characteristics for temperature range -40 °C to +85 °C and -40 °C to +125 °C
Voltages are referenced to GND (ground = 0 V); for test circuit, see Figure 6.
V
CC(A)
= V
CC(B)
1.2 V±0.1 V 1.5 V±0.1 V 1.8 V±0.15 V 2.5 V±0.2 V 3.3 V±0.3 V
Symbol Parameter Conditions
Max Max Max Max Max
Unit
T
amb
= -40 °C to +85 °C
t
sk(o)
output skew
time
between any
output
0.7 0.4 0.3 0.2 0.2 ns
T
amb
= -40 °C to +125 °C
t
sk(o)
output skew
time
between any
output
0.9 0.5 0.4 0.3 0.2 ns
Table 14. Typical power dissipation capacitance at T
amb
= 25 °C
[1]
[2]
V
CC(A)
= V
CC(B)
Symbol Parameter Conditions
0.8 V 1.2 V 1.5 V 1.8 V 2.5 V 3.3 V
Unit
Yn; outputs enabled 36 36 37 37 41 46 pFC
PD
power dissipation
capacitance
Yn; outputs disabled 2.9 3.2 3.4 3.5 3.7 3.9 pF
[1] C
PD
is used to determine the dynamic power dissipation (P
D
in μW).
P
D
= C
PD
× V
CC
2
× f
i
+ Σ(C
L
× V
CC
2
× f
o
) where:
f
i
= input frequency in MHz;
f
o
= output frequency in MHz;
C
L
= load capacitance in pF;
V
CC
= supply voltage in V;
Σ(C
L
× V
CC
2
× f
o
) = sum of the outputs.
[2] f
i
= 10 MHz;
V
I
= GND to V
CC(A)
;
t
r
= t
f
= 1 ns;
C
L
= 0 pF;
R
L
= ∞ Ω.
74AVC1T1004 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2018. All rights reserved.
Product data sheet Rev. 1 — 23 April 2018
10 / 22