Nexperia
74AVC1T1004
1-to-4 fan-out buffer
9 Recommended operating conditions
Table 6. Recommended operating conditions
Symbol Parameter Conditions Min Max Unit
V
CC(A)
supply voltage A 0.8 3.6 V
V
CC(B)
supply voltage B 0.8 3.6 V
V
I
input voltage 0 3.6 V
OE = LOW 0 V
CCB
VV
O
output voltage
OE = HIGH 0 3.6 V
T
amb
ambient temperature -40 +125 °C
Δt/ΔV input transition rise and fall rate V
CC(A)
= 0.8 V to 3.6 V 0 200 ns/V
10 Static characteristics
Table 7. Static characteristics
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
T
amb
= 25 °CSymbol Parameter Conditions
Min Typ Max
Unit
V
I
= V
IH
or V
IL
V
OH
HIGH-level output voltage
I
O
= -1.5 mA; V
CC(B)
= 0.8 V - 0.69 - V
V
I
= V
IH
or V
IL
V
OL
LOW-level output voltage
I
O
= 1.5 mA; V
CC(B)
= 0.8 V - 0.07 - V
I
I
input leakage current A, OE input; V
I
= 0 V or 3.6 V;
V
CC(A)
= V
CC(B)
= 0.8 V to 3.6 V
- ±0.025 ±0.25 μA
I
OFF
power-off leakage current V
I
or V
O
= 0 V to 3.6 V;
V
CC(A)
or V
CC(B)
= 0 V
- ±0.1 ±1 μA
R
pd
pull-down resistance - 50 - kΩ
C
I
input capacitance A, OE input; V
I
= 0 V or 3.3 V;
V
CC(A)
= 3.3 V
- 1.2 - pF
C
O
output capacitance Yn; V
O
= 3.3 V or 0 V; V
CC(B)
= 3.3 V - 4.7 - pF
Table 8. Static characteristics
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
T
amb
= -40 °C to +85 °C T
amb
= -40 °C to +125 °CSymbol Parameter Conditions
Min Max Min Max
Unit
A, OE input
V
CC(A)
= 0.8 V 0.70V
CC(A)
- 0.70V
CC(A)
- V
V
CC(A)
= 1.1 V to 1.95 V 0.65V
CC(A)
- 0.65V
CC(A)
- V
V
CC(A)
= 2.3 V to 2.7 V 1.6 - 1.6 - V
V
IH
HIGH-level input
voltage
V
CC(A)
= 3.0 V to 3.6 V 2 - 2 - V
74AVC1T1004 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2018. All rights reserved.
Product data sheet Rev. 1 — 23 April 2018
5 / 22