AD5379
Rev. B | Page 11 of 28
ABSOLUTE MAXIMUM RATINGS
T
A
= 25°C, unless otherwise noted.
Transient currents of up to 100 mA do not cause SCR latch-up.
Table 6.
Parameter Rating
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only, and functional operation of the device at these or
any other conditions above those listed in the operational
sections of this specification is not implied. Exposure to
absolute maximum rating conditions for extended periods may
affect device reliability.
V
DD
to AGND −0.3 V to +17 V
V
SS
to AGND −17 V to +0.3 V
V
CC
to DGND −0.3 V to +7 V
Digital Inputs to DGND −0.3 V to V
CC
+ 0.3 V
Digital Outputs to DGND −0.3 V to V
CC
+ 0.3 V
V
REF
1(+), V
REF
2(+) to AGND −0.3 V to +7 V
V
REF
1(−), V
REF
2(−) to AGND V
SS
− 0.3 V to V
DD
+ 0.3 V
V
BIAS
to AGND −0.3 V to +7 V
VOUT0–VOUT39 to AGND V
SS
− 0.3 V to V
DD
+ 0.3 V
REFGND to AGND V
SS
− 0.3 V to V
DD
+ 0.3 V
AGND to DGND −0.3 V to +0.3 V
Operating Temperature Range (T
A
)
Industrial (A Version) −40°C to +85°C
Storage Temperature Range −65°C to +150°C
Junction Temperature (T
J
max) 150°C
108-Lead CSPBGA Package
θ
JA
Thermal Impedance 37.5°C/W
θ
JC
Thermal Impedance 8.5°C/W
Reflow Soldering
Peak Temperature 230°C
Time at Peak Temperature 10 sec to 40 sec
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate
on the human body and test equipment and can discharge without detection. Although this product
features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to
high energy electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid
performance degradation or loss of functionality.