ABSOLUTE MAXIMUM RATINGS
Temperature under bias ................... -65°C to +135°C
Storage temperature ........................ -65°C to +150°C
Voltage on any pin with respect to VSS... -1.0V to +7V
D.C. output current (sink) ...................................10mA
Lead temperature (soldering, 10 seconds)........ 300°C
Table 2. Recommended Operating Conditions
COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only; functional operation of the
device (at these or any other conditions above those
listed in the operational sections of this specification) is
not implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.)
Notes: (1) The device enters the Active state after any start, and remains active until: (a) 9 clock cycles later if the Device Select Bits in the Slave
Address Byte are incorrect; or (b) 200nS after a stop ending a read operation.
(2) The device enters the Active state after any start, and remains active until t
WC
after a stop ending a write operation.
(3) The device goes into Standby: (a) 200nS after any stop, except those that initiate a nonvolatile write cycle; or (b) t
WC
after a stop that
initiates a nonvolatile cycle; or 9 clock cycles after any start that is not followed by the correct Device Select Bits in the Slave Address
Byte.
Temp Min. Max.
Commercial 0°C 70°C
Industrial -40°C +85°C
Symbol Parameter
V
CC
= 2.7 to 5.5V
Unit Test ConditionsMin Max
I
CC1
(1)
Active Supply Current Read 1.0 mA V
IL
= V
CC
x 0.1, V
IH
= V
CC
x 0.9
f
SCL
= 400kHz, SDA = Open
I
CC2
(2)
Active Supply Current Write 3.0 mA
I
SB1
(2)
Standby Current DC (WDT off) 1 µAV
SDA
=V
SCL
=V
CC
Others=GND or V
CC
I
SB2
(3)
Standby Current DC (WDT on) 30 µAV
SDA
=V
SCL
=V
CC
Others=GND or V
CC
I
LI
Input Leakage Current 10 µAV
IN
= GND to V
CC
I
LO
Output Leakage Current 10 µAV
SDA
= GND to V
CC
Device is in Standby
V
IL
Input LOW Voltage -1 V
CC
x 0.3 V
V
IH
Input HIGH Voltage V
CC
x 0.7 V
CC
+0.5 V
V
HYS
Schmitt Trigger Input Hysteresis
Fixed input level
V
CC
related level
0.2
.05 x V
CC
V
V
V
OL
Output LOW Voltage 0.4 V I
OL
= 1.0mA (V
CC
=3V)
I
OL
= 3.0mA (V
CC
=5V)
X40626