BTS426L1
Parameter and Conditions Symbol Values Unit
at Tj = 25 °C, V
bb
= 12 V unless otherwise specified
min typ max
Semiconductor Group 4 2003-Oct-01
Protection Functions
9)
Initial peak short circuit current limit (pin 3 to 5) I
L(SCp)
Tj
=-40°C:
Tj
=25°C:
Tj
=+150°C:
21
15
11
32
25
17
43
35
24
A
Repetitive short circuit shutdown current limit I
L(SCr)
T
j
= T
jt
(see timing diagrams, page 10) -- 16 -- A
Output clamp (inductive load switch off)
at V
OUT
= V
bb
- V
ON(CL)
I
L
= 40 mA:
V
ON(CL)
41
47 53 V
Thermal overload trip temperature T
jt
150 -- -- °C
Thermal hysteresis
T
jt
-- 10 -- K
Reverse battery (pin 3 to 1)
10)
-V
bb
-- -- 32 V
Reverse battery voltage drop (V
out
> V
bb
)
I
L
= -4 A T
j
=150 °C:
-V
ON(rev)
--
610
--
mV
Diagnostic Characteristics
Open load detection current T
j
=-40 °C:
(on-condition) T
j
=25 ..150°C:
I
L (OL)
20
10
--
--
850
750
mA
Open load detection voltage
11)
(off-condition) T
j
=-40..150°C: V
OUT(OL)
2 3 4 V
Internal output pull down
(pin 5 to 1), V
OUT
=5 V, T
j
=-40..150°C
R
O
4
10 30 k
9)
Integrated protection functions are designed to prevent IC destruction under fault conditions described in the data sheet. Fault
conditions are considered as "outside" normal operating range. Protection functions are not designed for continuous repetitive
operation.
10)
Requires 150 resistor in GND connection. The reverse load current through the intrinsic drain-source diode has to be limited by
the connected load. Note that the power dissipation is higher compared to normal operating conditions due to the voltage drop
across the intrinsic drain-source diode. The temperature protection is not active during reverse current operation! Input and Status
currents have to be limited (see max. ratings page 2 and circuit page 7).
11)
External pull up resistor required for open load detection in off state.
BTS426L1
Parameter and Conditions Symbol Values Unit
at Tj = 25 °C, V
bb
= 12 V unless otherwise specified
min typ max
Semiconductor Group 5 2003-Oct-01
Input and Status Feedback
12)
Input resistance
T
j
=-40..150°C, see circuit page 6
R
I
2.5 3.5 6 k
Input turn-on threshold voltage T
j
=-40..+150°C: V
IN(T+)
1.7 -- 3.5 V
Input turn-off threshold voltage T
j
=-40..+150°C: V
IN(T-)
1.5 -- -- V
Input threshold hysteresis V
IN(T)
-- 0.5 -- V
Off state input current (pin 2), V
IN
= 0.4 V,
T
j
=-40..+150°C
I
IN(off)
1 -- 50 µA
On state input current (pin 2), V
IN
= 3.5 V,
T
j
=-40..+150°C
I
IN(on)
20 50 90 µA
Delay time for status with open load after switch off
(see timing diagrams, page 11), T
j
=-40..+150°C
t
d(ST OL4)
100 520 1000 µs
Status invalid after positive input slope
(open load) T
j
=-40 ... +150°C:
t
d(ST)
-- 250 600 µs
Status output (open drain)
Zener limit voltage T
j
=-40...+150°C, I
ST
= +1.6 mA:
ST low voltage T
j
=-40...+25°C, I
ST
= +1.6 mA:
T
j
= +150°C, I
ST
= +1.6 mA:
V
ST(high)
V
ST(low)
5.4
--
--
6.1
--
--
--
0.4
0.6
V
12)
If a ground resistor R
GND
is used, add the voltage drop across this resistor.
BTS426L1
Semiconductor Group 6 2003-Oct-01
Truth Table
Input- Output Status
level
level 425 L1
426 L1
Normal
operation
L
H
L
H
H
H
Open load L
H
13
)
H
H (L
14)
)
L
Short circuit to
V
bb
L
H
H
H
L
15)
H (L
16)
)
Overtem-
perature
L
H
L
L
H
L
Undervoltage L
H
L
L
H
H
Overvoltage L
H
L
L
H
H
L = "Low" Level X = don't care Z = high impedance, potential depends on external circuit
H = "High" Level Status signal after the time delay shown in the diagrams (see fig 5. page 11...12)
13)
Power Transistor off, high impedance
14)
with external resistor between pin 3 and pin 5
15)
An external short of output to V
bb
, in the off state, causes an internal current from output to ground. If R
GND
is used, an offset
voltage at the GND and ST pins will occur and the V
ST low
signal may be errorious.
16)
Low resistance to V
bb
may be detected in ON-state by the no-load-detection
Terms
PROFET
V
IN
ST
OUT
GND
bb
V
ST
V
IN
I
ST
I
IN
V
bb
I
bb
I
L
V
OUT
I
GND
V
ON
1
2
4
3
5
R
GND
Input circuit (ESD protection)
IN
GND
I
R
ESD-ZD
I
I
I
ESD zener diodes are not to be used as voltage clamp at DC
conditions. Operation in this mode may result in a drift of the zener
voltage (increase of up to 1 V).

BTS426L1

Mfr. #:
Manufacturer:
Infineon Technologies
Description:
IC HIGH SIDE PWR SWITCH TO220-5
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet