AC Electrical Characteristics 22 May 24, 2006
IDT82V3011 T1/E1/OC3 WAN PLL WITH SINGLE REFERENCE INPUT
7.6 8 KHZ INPUT TO 8 KHZ OUTPUT JITTER TRANSFER
7.7 1.544 MHZ INPUT TO 1.544 MHZ OUTPUT JITTER TRANSFER
7.8 2.048 MHZ INPUT TO 2.048 MHZ OUTPUT JITTER TRANSFER
Description Min. Typ. Max. Units
Test Conditions / Notes
(see “Notes” on page 24)
Jitter attenuation for 1 Hz@0.01 UIpp input
0 6 dB 1, 4, 8-13, 20-21, 23, 27, 37
Jitter attenuation for 1 Hz@0.54 UIpp input 6 16 dB 1, 4, 8-13, 20-21, 23, 27, 37
Jitter attenuation for 10 Hz@0.10 UIpp input 15 22 dB 1, 4, 8-13, 20-21, 23, 27, 37
Jitter attenuation for 60 Hz@0.10 UIpp input 32 38 dB 1, 4, 8-13, 20-21, 23, 27, 37
Jitter attenuation for 300 Hz@0.10 UIpp input 42 dB 1, 4, 8-13, 20-21, 23, 27, 37
Jitter attenuation for 3600 Hz@0.005 UIpp input 50 dB 1, 4, 8-13, 20-21, 23, 27, 37
Description Min. Typ. Max. Units
Test Conditions / Notes
(see “Notes” on page 24)
Jitter attenuation for 1 Hz@20 UIpp input
0 6 dB 1, 5, 8-13, 20-21, 23, 28, 37
Jitter attenuation for 1 Hz@104 UIpp input 6 16 dB 1, 5, 8-13, 20-21, 23, 28, 37
Jitter attenuation for 10 Hz@20 UIpp input 17 22 dB 1, 5, 8-13, 20-21, 23, 28, 37
Jitter attenuation for 60 Hz@20 UIpp input 33 38 dB 1, 5, 8-13, 20-21, 23, 28, 37
Jitter attenuation for 300 Hz@20 UIpp input 45 dB 1, 5, 8-13, 20-21, 23, 28, 37
Jitter attenuation for 10 kHz@0.3 UIpp input 48 dB 1, 5, 8-13, 20-21, 23, 28, 37
Jitter attenuation for 40 kHz@0.3 UIpp input 50 dB 1, 5, 8-13, 20-21, 23, 28, 37
Description Min. Typ. Max. Units
Test Conditions / Notes
(see “Notes” on page 24)
Jitter at output for 1 Hz@3.00 UIpp input
2.5 UIpp 1, 6, 8-13, 20-21, 23, 29, 37
Jitter at output for 1 Hz@3.00 UIpp input with 40 Hz to 100 kHz filter 0.07 UIpp 1, 6, 8-13, 20-21, 23, 29, 38
Jitter at output for 3 Hz@2.33 UIpp input 1.4 UIpp 1, 6, 8-13, 20-21, 23, 29, 37
Jitter at output for 3 Hz@2.33 UIpp input with 40 Hz to 100 kHz filter 0.10 UIpp 1, 6, 8-13, 20-21, 23, 29, 38
Jitter at output for 5 Hz@2.07 UIpp input 0.90 UIpp 1, 6, 8-13, 20-21, 23, 29, 37
Jitter at output for 5 Hz@2.07 UIpp input with 40 Hz to 100 kHz filter 0.10 UIpp 1, 6, 8-13, 20-21, 23, 29, 38
Jitter at output for 10 Hz@1.76 UIpp input 0.40 UIpp 1, 6, 8-13, 20-21, 23, 29, 37
Jitter at output for 10 Hz@1.76 UIpp input with 40 Hz to 100 kHz filter 0.10 UIpp 1, 6, 8-13, 20-21, 23, 29, 38
Jitter at output for 100 Hz@1.50 UIpp input 0.06 UIpp 1, 6, 8-13, 20-21, 23, 29, 37
Jitter at output for 100 Hz@1.50 UIpp input with 40 Hz to 100 kHz filter 0.05 UIpp 1, 6, 8-13, 20-21, 23, 29, 38
Jitter at output for 2400 Hz@1.50 UIpp input 0.04 UIpp 1, 6, 8-13, 20-21, 23, 29, 37
Jitter at output for 2400 Hz@1.50 UIpp input with 40 Hz to 100 kHz filter 0.03 UIpp 1, 6, 8-13, 20-21, 23, 29, 38
Jitter at output for 100 kHz@0.20 UIpp input 0.04 UIpp 1, 6, 8-13, 20-21, 23, 29, 37
Jitter at output for 100 kHz@0.20 UIpp input with 40 Hz to 100 kHz filter 0.02 UIpp 1, 6, 8-13, 20-21, 23, 29, 38
AC Electrical Characteristics 23 May 24, 2006
IDT82V3011 T1/E1/OC3 WAN PLL WITH SINGLE REFERENCE INPUT
7.9 19.44 MHZ INPUT TO 19.44 MHZ OUTPUT JITTER TRANSFER
7.10 8 KHZ INPUT JITTER TOLERANCE
7.11 1.544 MHZ INPUT JITTER TOLERANCE
Description Min. Typ. Max. Units
Test Conditions / Notes
(see “Notes” on page 24)
Jitter attenuation for 1 Hz@20 UIpp input
0 6 dB 1, 7-13, 20-21, 23, 35, 37
Jitter attenuation for 1 Hz@104 UIpp input 6 16 dB 1, 7-13, 20-21, 23, 35, 37
Jitter attenuation for 10 Hz@20 UIpp input 17 22 dB 1, 7-13, 20-21, 23, 35, 37
Jitter attenuation for 60 Hz@20 UIpp input 33 38 dB 1, 7-13, 20-21, 23, 35, 37
Jitter attenuation for 300 Hz@20 UIpp input 45 dB 1, 7-13, 20-21, 23, 35, 37
Jitter attenuation for 10 kHz@0.3 UIpp input 48 dB 1, 7-13, 20-21, 23, 35, 37
Jitter attenuation for 40 kHz@0.3 UIpp input 50 dB 1, 7-13, 20-21, 23, 35, 37
Description Min. Typ. Max. Units
Test Conditions / Notes
(see “Notes” on page 24)
Jitter tolerance for 1 Hz input
0.80 UIpp 1, 4, 8-13, 20-21, 23-25, 27
Jitter tolerance for 5 Hz input 0.70 UIpp 1, 4, 8-13, 20-21, 23-25, 27
Jitter tolerance for 20 Hz input 0.60 UIpp 1, 4, 8-13, 20-21, 23-25, 27
Jitter tolerance for 300 Hz input 0.16 UIpp 1, 4, 8-13, 20-21, 23-25, 27
Jitter tolerance for 400 Hz input 0.14 UIpp 1, 4, 8-13, 20-21, 23-25, 27
Jitter tolerance for 700 Hz input 0.07 UIpp 1, 4, 8-13, 20-21, 23-25, 27
Jitter tolerance for 2400 Hz input 0.02 UIpp 1, 4, 8-13, 20-21, 23-25, 27
Jitter tolerance for 3600 Hz input 0.01 UIpp 1, 4, 8-13, 20-21, 23-25, 27
Description Min. Typ. Max. Units
Test Conditions / Notes
(see “Notes” on page 24)
Jitter tolerance for 1 Hz input
150 UIpp 1, 5, 8-13, 20-21, 23-25, 28
Jitter tolerance for 5 Hz input 140 UIpp 1, 5, 8-13, 20-21, 23-25, 28
Jitter tolerance for 20 Hz input 130 UIpp 1, 5, 8-13, 20-21, 23-25, 28
Jitter tolerance for 300 Hz input 38 UIpp 1, 5, 8-13, 20-21, 23-25, 28
Jitter tolerance for 400 Hz input 25 UIpp 1, 5, 8-13, 20-21, 23-25, 28
Jitter tolerance for 700 Hz input 15 UIpp 1, 5, 8-13, 20-21, 23-25, 28
Jitter tolerance for 2400 Hz input 5 UIpp 1, 5, 8-13, 20-21, 23-25, 28
Jitter tolerance for 10 kHz input 1.2 UIpp 1, 5, 8-13, 20-21, 23-25, 28
Jitter tolerance for 40 kHz input 0.5 UIpp 1, 5, 8-13, 20-21, 23-25, 28
AC Electrical Characteristics 24 May 24, 2006
IDT82V3011 T1/E1/OC3 WAN PLL WITH SINGLE REFERENCE INPUT
7.12 2.048 MHZ INPUT JITTER TOLERANCE
7.13 19.44 MHZ INPUT JITTER TOLERANCE
Notes:
Voltages are with respect to ground (V
SS
) unless otherwise stated. Supply voltage and operating temperature are as per Recommended Operating Conditions. Timing parameters are
as per Timing Parameter Measurement Voltage Levels.
1. Normal mode selected.
2. Holdover mode selected.
3. Freerun mode selected.
4. 8 kHz frequency mode selected.
5. 1.544 MHz frequency mode selected.
6. 2.048 MHz frequency mode selected.
7. 19.44 MHz frequency mode selected.
8. Master clock input OSCi at 20 MHz ±0 ppm.
9. Master clock input OSCi at 20 MHz ±32 ppm.
10. Master clock input OSCi at 20 MHz ±100 ppm.
11. Reference input at ±0 ppm.
12. Reference input at ±32 ppm.
13. Reference input at ±100 ppm.
14. For Freerun mode of ±0 ppm.
15. For Freerun mode of ±32 ppm.
16. For Freerun mode of ±100 ppm.
17. For capture range of ±230 ppm.
18. For capture range of ±198 ppm.
19. For capture range of ±130 ppm.
20. 25 pF capacitive load.
Description Min. Typ. Max. Units
Test Conditions / Notes
(see “Notes” on page 24)
Jitter tolerance for 1 Hz input
150 UIpp 1, 6, 8-13, 20-21, 23-25, 29
Jitter tolerance for 5 Hz input 140 UIpp 1, 6, 8-13, 20-21, 23-25, 29
Jitter tolerance for 20 Hz input 130 UIpp 1, 6, 8-13, 20-21, 23-25, 29
Jitter tolerance for 300 Hz input 40 UIpp 1, 6, 8-13, 20-21, 23-25, 29
Jitter tolerance for 400 Hz input 33 UIpp 1, 6, 8-13, 20-21, 23-25, 29
Jitter tolerance for 700 Hz input 18 UIpp 1, 6, 8-13, 20-21, 23-25, 29
Jitter tolerance for 2400 Hz input 5.5 UIpp 1, 6, 8-13, 20-21, 23-25, 29
Jitter tolerance for 10 kHz input 1.3 UIpp 1, 6, 8-13, 20-21, 23-25, 29
Jitter tolerance for 100 kHz input 0.4 UIpp 1, 6, 8-13, 20-21, 23-25, 29
Description Min. Typ. Max. Units
Test Conditions / Notes
(see “Notes” on page 24)
Jitter tolerance for 12 µHz input
2800 UIpp 1, 7-13, 20-21, 23-25, 35
Jitter tolerance for 178 µHz input 2800 UIpp 1, 7-13, 20-21, 23-25, 35
Jitter tolerance for 0.0016 Hz input 311 UIpp 1, 7-13, 20-21, 23-25, 35
Jitter tolerance for 0.0156 Hz input 311 UIpp 1, 7-13, 20-21, 23-25, 35
Jitter tolerance for 0.125 Hz input 39 UIpp 1, 7-13, 20-21, 23-25, 35
Jitter tolerance for 19.3 Hz input 39 UIpp 1, 7-13, 20-21, 23-25, 35
Jitter tolerance for 500 Hz input 1.5 UIpp 1, 7-13, 20-21, 23-25, 35
Jitter tolerance for 6.5 kHz input 1.5 UIpp 1, 7-13, 20-21, 23-25, 35
Jitter tolerance for 65 kHz input 0.15 UIpp 1, 7-13, 20-21, 23-25, 35
Jitter tolerance for 1.3 MHz input 0.15 UIpp 1, 7-13, 20-21, 23-25, 35

82V3011PVG

Mfr. #:
Manufacturer:
IDT
Description:
Clock Generators & Support Products T1/E1/OC3 WAN PLL
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet