www.vishay.com
10
Document Number: 70049
S09-2561-Rev. I, 30-Nov-09
Vishay Siliconix
DG401, DG403, DG405
APPLICATIONS
Dual Slope Integrators:
The DG403 is well suited to configure a selectable slope
integrator. One control signal selects the timing capacitor C
1
or C
2
. Another one selects e
in
or discharges the capacitor in
preparation for the next integration cycle.
Band-Pass Switched Capacitor Filter:
Single-pole double-throw switches are a common element
for switched capacitor networks and filters. The fast
switching times and low leakage of the DG403 allow for
higher clock rates and consequently higher filter operating
frequencies.
Figure 9. Stereo Source Selector
DG403
Right
Right
Left
Left
Channel
Select
Source 1
Source 2
TTL
Left
Right
- 15 V
+ 15 V+ 5 V
GND V-
V+
S
1
IN
2
S
3
S
2
S
4
D
1
D
3
D
2
D
4
V
L
IN
1
Figure 10. Dual Slope Integrator
DG403
Integrate/
Reset
Slope
Select
TTL
+
-
- 15 V
+ 15 V+ 5 V
GND V-
V+
S
1
IN
2
S
3
S
2
S
4
D
1
D
3
D
2
D
4
V
L
IN
1
C
1
C
2
e
out
e
in
Figure 11. Band-Pass Switched Capacitor Filter
- 15 V
+ 15 V+ 5 V
GND V-
V+
Clock
+
-
V
L
e
out
e
in
DG403
S
1
IN
2
S
3
S
2
S
4
D
1
D
3
D
2
D
4
IN
1