MPX4115A
Rev 5, 1/2009
Freescale Semiconductor
© Freescale Semiconductor, Inc., 2006-2009. All rights reserved.
Pressure
Media Resistant, Integrated Silicon
Pressure Sensor for Manifold
Absolute Pressure, Altimeter or
Barometer Applications On-Chip
Signal Conditioned, Temperature
Compensated and Calibrated
The MPX4115A series is designed to sense absolute air pressure in
altimeter or barometer (BAP) applications. Freescale's BAP sensor integrates
on-chip, bipolar op amp circuitry and thin film resistor networks to provide a
high level analog output signal and temperature compensation. The small form
factor and high reliability of on-chip integration makes the Freescale BAP
sensor a logical and economical choice for application designers.
Features
1.5% Maximum Error Over 0° to 85°C
Ideally Suited for Microprocessor Interfacing or Microcontroller-Based Systems
Temperature Compensated Over -40°C to +125°C
Durable Epoxy Unibody Element or Thermoplastic (PPS) Surface Mount Package
Available as Standard Fluorosilicone Gel (MPXA4115A, MPX4115A) or Media Resistant Gel (MPXAZ4115A)
ORDERING INFORMATION
Device Name
Package
Options
Case
No.
# of Ports Pressure Type
Device Marking
None Single Dual Gauge Differential Absolute
Unibody Package (MPX4115A Series)
MPX4115A
Tray 867-08
MPX4115A
MPX4115AP
Tray 867B-04
MPX4115AP
MPX4115AS
Tray 867E-03
MPX4115A
Small Outline Package (Media Resistant Gel) (MPXAZ4115A Series)
MPXAZ4115A6U
Rails 482
MPXAZ4115A
MPXAZ4115AC6U
Rails 482A
MPXAZ4115A
MPXAZ4115A6T1
Tape and Reel 482
MPXAZ4115A
Small Outline Package (MPXA4115A Series)
MPXA4115AC6U
Rails 482A
MPXA4115A
MPXA4115AP
Tray 1369-01
MPXA4115AP
MPXA4115A6T1
Tape and Reel 482
MPXA4115A
MPXA4115A6U
Rails 482
MPXA4115A
MPX4115A
INTEGRATED
PRESSURE SENSOR
15 to 115 kPa (2.2 to 16.7 psi)
0.2 to 4.8 V Output
Series
Application Examples
Altimeter
Barometer
Aviation Altimeters
Industrial Controls
Engine Control
Weather Stations and Weather
Reporting Devices
MPX4115A
Sensors
2 Freescale Semiconductor
Pressure
MPX4115A
CASE 867-08
MPX4115AP
CASE 867B-04
MPX4115AS
CASE 867E-03
MPXAZ4115A6U/T1
MPXA4115A6U/T1
CASE 482-01
MPXAZ4115AC6U
MPXA4115AC6U
CASE 482A-01
SMALL OUTLINE PACKAGES
UNIBODY PACKAGES
MPXA4115AP
CASE 1369-01
MPX4115A
Sensors
Freescale Semiconductor 3
Pressure
Operating Characteristics
Table 1. Operating Characteristics (V
S
= 5.1 Vdc, T
A
= 25°C unless otherwise noted, P1 > P2. Decoupling circuit shown in
Figure 3 required to meet electrical specifications.)
Characteristic Symbol Min Typ Max Unit
Pressure Range
(1)
1. 1.0 kPa (kiloPascal) equals 0.145 psi.
P
OP
15 115 kPa
Supply Voltage
(2)
2. Device is ratiometric within this specified excitation range.
V
S
4.85 5.1 5.35 Vdc
Supply Current I
o
7.0 10 mAdc
Minimum Pressure Offset (0 to 85°C)
@ V
S
= 5.1 Volts
(3)
3. Offset (V
off
) is defined as the output voltage at the minimum rated pressure.
V
off
0.135 0.204 0.273 Vdc
Full Scale Output (0 to 85°C)
@ V
S
= 5.1 Volts
(4)
4. Full Scale Output (V
FSO
) is defined as the output voltage at the maximum or full rated pressure.
V
FSO
4.725 4.794 4.863 Vdc
Full Scale Span (0 to 85°C)
@ V
S
= 5.1 Volts
(5)
5. Full Scale Span (V
FSS
) is defined as the algebraic difference between the output voltage at full rated pressure and the output voltage at the
minimum rated pressure.
V
FSS
4.521 4.59 4.659 Vdc
Accuracy
(6)
(0 to 85°C)
6. Accuracy (error budget) consists of the following:
Linearity: Output deviation from a straight line relationship with pressure over the specified pressure range.
Temperature Hysteresis: Output deviation at any temperature within the operating temperature range, after the temperature is cycled to
and from the minimum or maximum operating temperature points, with zero differential pressure applied.
Pressure Hysteresis: Output deviation at any pressure within the specified range, when this pressure is cycled to and from the
minimum or maximum rated pressure, at 25°C.
TcSpan: Output deviation over the temperature range of 0 to 85°C, relative to 25°C.
TcOffset: Output deviation with minimum rated pressure applied, over the temperature range of 0 to 85°C, relative to 25°C.
Variation from Nominal: The variation from nominal values, for Offset or Full Scale Span, as a percent of V
FSS
, at 25°C.
——±1.5 %V
FSS
Sensitivity V/P 46 mV/kPa
Response Time
(7)
7. Response Time is defined as the time for the incremental change in the output to go from 10% to 90% of its final value when subjected to a
specified step change in pressure.
t
R
—1.0—ms
Output Source Current at Full Scale Output l
o
+ 0.1 mAdc
Warm-Up Time
(8)
8. Warm-up Time is defined as the time required for the product to meet the specified output voltage after the Pressure has been stabilized.
——20mSec
Offset Stability
(9)
9. Offset Stability is the product's output deviation when subjected to 1000 hours of Pulsed Pressure, Temperature Cycling with Bias Test.
——±0.5 %V
FSS