Document Number: 001-10261 Rev. *H Page 3 of 10
Programming Description
The CY2X013 is a programmable device. Prior to being used in
an application, it must be programmed with the output frequency
and other variables described in Programming Variables. Two
different device types are available, each with its own
programming flow. They are described in the following sections.
Field Programmable CY2X013F
Field programmable devices are shipped unprogrammed and
must be programmed before being installed on a PCB.
Customers use CyClockWizard™ software to specify the device
configuration and generate a joint electron devices engineering
council (JEDEC - extension .jed) programming file.
Programming of samples and prototype quantities is available
using the CyClockWizard software along with a
CY3675-CLKMAKER1 CyClockMaker Clock Programmer Kit
with a CY3675-LCC6A socket adapter. Cypress’s value-added
distribution partners also provide programming
services. Field-programmable devices are designated with an ‘F’
in the part number. They are intended for quick prototyping and
inventory reduction.
You can download the software and programmer kit hardware
from www.cypress.com by clicking the hyperlinks in the previous
paragraph.
Factory Configured CY2X013
For ready-to-use devices, the CY2X013 is available with no field
programming required. Pre-configured devices (see Standard
and Application-Specific Factory Configurations) are available
for samples or orders, or a request for a custom configuration
can be made. All requests are submitted to the local Cypress
field application engineer (FAE) or sales representative. After the
request is processed, the user receives a new part number,
samples, and datasheet with the programmed values. This part
number is used for additional sample requests and production
orders. The CY2X013 is one-time programmable (OTP).
Programming Variables
Output Frequency
The CY2X013 can synthesize a frequency to a resolution of one
part per million (ppm), but the actual accuracy of the output
frequency is limited by the accuracy of the integrated reference
crystal.
The CY2X013 has an output frequency range of 50 MHz to
690 MHz, but the range is not continuous. The CY2X013 cannot
generate frequencies in the ranges of 521 MHz to 529 MHz and
596 MHz to 617 MHz.
Pin 1: Output Enable (OE) or Power-Down (PD#)
Pin 1 is programmed as either OE or PD#. The OE function is
used to enable or disable the CLK output quickly, but it does not
reduce core power consumption. The PD# function puts the
device into a low-power state, but the wake-up takes longer
because the PLL must reacquire the lock.
Industrial versus Commercial Device Performance
Industrial and commercial devices have different internal
crystals. They have a potentially significant impact on
performance levels for applications requiring the lowest possible
phase noise. CyClockWIzard software allows the user to select
between and view the expected performance of both options.
Table 2. Device Programming Variables
Variable
Output frequency
Pin 1 function (OE or PD#)
Temperature range (commercial or industrial)