Typical operating circuit STPIC6C595
10/22
Figure 6. Typical operation mode test circuits
Figure 7. Switching time waveform
Figure 8. Input setup and hold waveform
Note: 1 A) The word generator has the following characteristics: t
r
10 ns, t
f
10 ns, t
W
= 300 ns,
pulse repetition rate (PRR) = 5 kHz, Z
O
= 50
Ω
2B) C
L
includes probe and jig capacitance.
STPIC6C595 Typical operating circuit
11/22
Figure 9. Reverse recovery current test circuits
Figure 10. Source drain diode waveform
Note: 1 A) The V
GG
amplitude and R
G
are adjusted for di/dt = 10 A/
μ
s. A V
GG
double-pulse train is
used to set I
F
= 0.1 A. where t
1
= 10
μ
s, t
2
= 7
μ
s and t
3
= 3
μ
s
2 B) The drain terminal under test is connected to the TPK test point. All other terminals are
connected together and connected to the TPA test point.
3C) I
RM
= maximum recovery current.
Typical operating circuit STPIC6C595
12/22
Figure 11. Single pulse avalanche energy test circuits
Figure 12. Single pulse avalanche energy waveform
Note: 1 A) The word generator has the following characteristics: t
r
10 ns, t
f
10 ns, Z
O
= 50
Ω
2 B) Input pulse duration, t
W
is increased until peak current I
AS
= 200 mA. Energy test level is
defined as E
AS
= (I
AS
x V
(BR)DSX
x t
AV
)/2 = 30 mJ.

STPIC6C595MTR

Mfr. #:
Manufacturer:
STMicroelectronics
Description:
Counter Shift Registers 8-Bit Shift Register
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet