lengths and use sufficient trace width to reduce inductance.
Use of surface-mount components is recommended.
Supply Sequencing
V
SS
must be lower than or equal to the more negative
voltage of V
NN1
or V
NN2
at all times, and must be
turned on before other supply voltages. No other
power-supply sequencing is required for the MAX4806/
MAX4807/MAX4808.
Typical Application Circuits
Figures 8, 9, and 10 show typical applications for the
MAX4806/MAX4807/MAX4808. Figure 8 shows the
MAX4806 used in a bipolar pulsing connection.
Figure 9 shows the MAX4807 in a five-level pulsing
application, and Figure 10 shows the MAX4808 used in
a unipolar application.
MAX4806/MAX4807/MAX4808
Dual, Unipolar/Bipolar, High-Voltage
Digital Pulsers
______________________________________________________________________________________ 13