Regulatory Information
The HCPL-3150 and HCPL-315J have been approved by the following organizations:
UL
Recognized under UL 1577, Component Recognition Program, File E55361.
CSA
Approved under CSA Component Acceptance Notice #5, File CA 88324.
IEC/EN/DIN EN 60747-5-5
Approved under: DIN EN 60747-5-5(VDE 0884-5):2011-11 (Option 060 and HCPL-315J only)
Recommended Pb-Free IR Prole
Recommended reow condition as per JEDEC Standard, J-STD-020 (latest revision). Non-Halide Flux should be used.
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics
Description Symbol HCPL-3150#060 HCPL-315J Unit
Installation classication per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 Vrms
for rated mains voltage ≤ 1000Vrms
I - IV
I - III
I - II
I - IV
I - IV
I - IV
I-III
Climatic Classication 55/100/21 55/100/21
Pollution Degree (DIN VDE 0110/1.89) 2 2
Maximum Working Insulation Voltage V
IORM
630 1414 Vpeak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production Test with t
m
= 1 sec,
Partial discharge < 5 pC
V
PR
1181 2652 Vpeak
Input to Output Test Voltage, Method a*
V
IORM
x 1.6 = V
PR
, Type and Sample Test, t
m
= 10 sec,
Partial discharge < 5 pC
V
PR
945 2262 Vpeak
Highest Allowable Overvoltage*
(Transient Overvoltage t
ini
= 60 sec)
V
IOTM
6000 8000 Vpeak
Safety-Limiting Values – Maximum Values Allowed in the
Event of a Failure, Also See Figure 37, Thermal Derating Curve.
Case Temperature
Input Current
Output Power
T
S
I
S, INPUT
P
S, OUTPUT
175
230
600
175
400
1200
°C
mA
mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
≥ 10
9
≥ 10
9
Ω
* Refer to IEC/EN/DIN EN 60747-5-5 Optoisolator Safety Standard section of the Avago Regulatory Guide to Isolation Circuits, AV02-2041EN for a
detailed description of Method a and Method b partial discharge test proles.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.