IR2132
B-174 CONTROL INTEGRATED CIRCUIT DESIGNERS MANUAL
Figure 16A. ITRIP to
FAULT
Indication Time vs.
Temperature
Figure 16B. ITRIP to
FAULT
Indication Time vs.
Voltage
Figure 15B. ITRIP to Output Shutdown Time vs. VoltageFigure 15A. ITRIP to Output Shutdown Time vs.
Temperature
Figure 17A.
LIN1,2,3
to
FAULT
Clear Time vs.
Temperature
Figure 17B.
LIN1,2,3
to
FAULT
Clear Time vs. Voltage
0.00
0.30
0.60
0.90
1.20
1.50
-50 -25 0 25 50 75 100 125
Temperature (°C)
ITRIP to Output Shutdown Delay Time (µs
)
Typ.
Min.
Max.
0.00
0.30
0.60
0.90
1.20
1.50
10 12 14 16 18 20
V
BIAS
Supply Voltage (V)
ITRIP to Output Shutdown Delay Time (µs
)
Max.
Typ.
Min.
0.0
5.0
10.0
15.0
20.0
25.0
-50 -25 0 25 50 75 100 125
Temperature (°C)
L
IN1,2,3 to FAULT Clear Time (µ
s)
Typ.
Min.
Max.
0.00
0.30
0.60
0.90
1.20
1.50
10 12 14 16 18 20
V
CC
Supply Voltage (V)
I
TRIP to FAULT Indication Delay Time (µ
s)
Max.
Typ.
Min.
0.00
0.30
0.60
0.90
1.20
1.50
-50 -25 0 25 50 75 100 125
Temperature (°C)
I
TRIP to FAULT Indication Delay Time (µ
s)
Typ.
Min.
Max.
0.0
5.0
10.0
15.0
20.0
25.0
10 12 14 16 18 20
V
CC
Supply Voltage (V)
L
IN1,2,3 to FAULT Clear Time (µ
s)
Max.
Typ.
Min.
IR2132
CONTROL INTEGRATED CIRCUIT DESIGNERS MANUAL B-175
Figure 19A. Amplifier Slew Rate (+) vs. Temperature Figure 19B. Amplifier Slew Rate (+) vs. Voltage
Figure 18A. Deadtime vs. Temperature Figure 18B. Deadtime vs. Voltage
Figure 20A. Amplifier Slew Rate (-) vs. Temperature Figure 20B. Amplifier Slew Rate (-) vs. Voltage
0.0
2.0
4.0
6.0
8.0
10.0
-50 -25 0 25 50 75 100 125
Temperature (°C)
Amplifier Slew Rate + (V/µ
s)
Typ.
Min.
0.0
2.0
4.0
6.0
8.0
10.0
10 12 14 16 18 20
V
CC
Supply Voltage (V)
Amplifier Slew Rate + (V/µ
s)
Min.
Typ.
0.00
1.00
2.00
3.00
4.00
5.00
-50 -25 0 25 50 75 100 125
Temperature (°C)
Amplifier Slew Rate - (V/µ
s)
Typ.
Min.
0.00
1.00
2.00
3.00
4.00
5.00
10 12 14 16 18 20
V
CC
Supply Voltage (V)
Amplifier Slew Rate - (V/µ
s)
Min.
Typ.
0.00
0.50
1.00
1.50
2.00
2.50
-50 -25 0 25 50 75 100 125
Temperature (°C)
D
eadtime (µs
)
Typ.
Min.
Max.
0.00
0.50
1.00
1.50
2.00
2.50
10 12 14 16 18 20
V
BIAS
Supply Voltage (V)
Deadtime (µs
)
Max.
Typ.
Min.
IR2132
B-176 CONTROL INTEGRATED CIRCUIT DESIGNERS MANUAL
Figure 22A. Logic “1” Input Threshold vs. Temperature Figure 22B. Logic “1” Input Threshold vs. Voltage
Figure 21A. Logic “0” Input Threshold vs. Temperature Figure 20B. Logic “0” Input Threshold vs. Voltage
Figure 23A. ITRIP Input Positive Going Threshold
vs. Temperature
Figure 23B. ITRIP Input Positive Going Threshold
vs. Voltage
0
150
300
450
600
750
-50 -25 0 25 50 75 100 125
Temperature (°C)
ITRIP Input Positive Going Threshold (mV
)
Typ.
Min.
Max.
0
150
300
450
600
750
10 12 14 16 18 20
V
CC
Supply Voltage (V)
I
TRIP Input Positive Going Threshold (mV
)
Max.
Typ.
Min.
0.00
1.00
2.00
3.00
4.00
5.00
-50 -25 0 25 50 75 100 125
Temperature (°C)
L
ogic "0" Input Threshold (V
)
Min.
0.00
1.00
2.00
3.00
4.00
5.00
10 12 14 16 18 20
V
CC
Supply Voltage (V)
L
ogic "0" Input Threshold (V
)
Min.
0.00
1.00
2.00
3.00
4.00
5.00
-50 -25 0 25 50 75 100 125
Temperature (°C)
L
ogic "1" Input Threshold (V
)
Max.
0.00
1.00
2.00
3.00
4.00
5.00
10 12 14 16 18 20
V
CC
Supply Voltage (V)
L
ogic "1" Input Threshold (V
)
Max.

IR2132JTR