AD677
REV. A
–5–
WARNING!
ESD SENSITIVE DEVICE
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the AD677 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
ORDERING GUIDE
Temperature Package
Model Range S/(N+D) Max INL Package Description Option*
AD677JN 0°C to +70°C 89 dB Typ Only Plastic 16-Pin DIP N-16
AD677KN 0°C to +70°C 90 dB ±1.5 LSB Plastic 16-Pin DIP N-16
AD677JD 0°C to +70°C 89 dB Typ Only Ceramic 16-Pin DIP D-16
AD677KD 0°C to +70°C 90 dB ±1.5 LSB Ceramic 16-Pin DIP D-16
AD677JR 0°C to +70°C 89 dB Typ Only Plastic 28-Lead SOIC R-28
AD677KR 0°C to +70°C 90 dB ±1.5 LSB Plastic 28-Lead SOIC R-28
AD677AD –40°C to +85°C 89 dB Typ Only Ceramic 16-Pin DIP D-16
AD677BD –40°C to +85°C 90 dB ±1.5 LSB Ceramic 16-Pin DIP D-16
*D = Ceramic DIP; N = Plastic DIP; R = Small Outline IC (SOIC).
ABSOLUTE MAXIMUM RATINGS*
V
CC
to V
EE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +26.4 V
V
DD
to DGND . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +7 V
Vcc to AGND . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +18 V
VEE to AGND . . . . . . . . . . . . . . . . . . . . . . . . . . –18 V to +0.3 V
AGND to DGND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +0.3 V
Digiul Inputs to DGND . . . . . . . . . . . . . . . . . . . . . . 0 to +5.5 V
Analog Inputs, V
REF
to AGND
. . . . . . . . . . . . . . . . . . . . . . . . . . . . (V
CC
+0.3 V) to (V
EE
–0.3 V)
Soldering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +300°C, 10 sec
Storage Temperature . . . . . . . . . . . . . . . . . . . . .–65°C to +150°C
*Stresses greater than those listed under “Absolute Maximum Ratings” may cause
permanent damage to the device. This is a stress rating only and functional
operation of the device at these or any other conditions above those indicated in the
operational section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.