7210_en_02 PHOENIX CONTACT 13
9.4 Permissible characteristics according to the jumper supply
The table below indicates which characteristic can be configured for which jumper supply.
10 Programming data/configuration data
Local bus (INTERBUS)) Other bus systems
11 Process data
The terminal occupies three process data words and one PCP word.
Figure 7 Order of the process data words
Characteristic U
V
= 3.3 V U
V
= 5 V
+1 mV/V Yes Yes
±1 mV/V Yes Yes
+2 mV/V Yes Yes
±2 mV/V Yes Yes
+3 mV/V Yes Yes
±3 mV/V Yes No
+4 mV/V Yes Yes
±4 mV/V Yes No
ID code DF
hex
(223
dec
)
Length code 03
hex
Process data channel 48 bits
Input address area 3 words
Output address area 3 words
Parameter channel (PCP) 1 word
Register length (bus) 4 words
For the programming/configuration data of
other bus systems, please refer to the
corresponding electronic device data sheet
(e.g., GSD, EDS).
IB IL SGI 2/F ...
7210_en_02 PHOENIX CONTACT 14
12 OUT process data output words
Three OUT process data words are available.
Configure the terminal channels via the OUT process data words.
Where:
Output word OUT1 contains the command
Output word OUT2 contains the parameters for channel 1
Output word OUT3 contains the parameters for channel 2
The following configurations are possible:
Configuration errors are indicated in the status word. The configuration settings are stored in a volatile memory.
If you change the configuration, the message "Measured value invalid" appears (diagnostic code 8004
hex
), until new
measured values are available.
12.1 Output word OUT1 (control word)
Bit 15 to bit 8 (command code):
Configuration Short designation Default
Selection of mean value generation (filtering) Filter 16-sample mean value
Characteristic for calculating the gain (see "Startup/measuring jumper
detuning" on page 21)
Characteristic ±2 mV/V
OUT1
Bit 1514131211109876543210
Assignment
Command code 00000000
Bit 15 to bit 8 OUT1 Command function
0 0 0 0 0 0 0 0 0000
hex
Read measured values
0 0 0 1 0 0 0 C 1x00
hex
Read configuration channel-by-channel in IN2
(C = Channel number; 0 = Channel 1, 1 = Channel 2)
0 0 1 1 0 0 0 0 3000
hex
Read min. value; IN2: Min. value channel 1, IN3: Min. value channel 2
0 0 1 1 0 0 0 1 3100
hex
Read max. value; IN2: Max. value channel 1, IN3: Max. value channel 2
0 0 1 1 0 0 1 0 3200
hex
Delete minimum and maximum value of channel 1
0 0 1 1 0 0 1 1 3300
hex
Delete minimum and maximum value of channel 2
0 0 1 1 1 1 0 03C00
hex
Read firmware version and module ID in IN2.
0 1 0 0 0 0 0 0 4000
hex
Configure device;
configuration for channel 1 in OUT2 and for channel 2 in OUT3
During the transient response (e.g., following a configuration command), the fluctuating measured values may
exceed the minimum and maximum values. Therefore, at the start of acquisition delete the minimum and
maximum values using command 3200
hex
and/or 3300
hex
.
One measurement is performed for each bus cycle.
IB IL SGI 2/F ...
7210_en_02 PHOENIX CONTACT 15
12.2 Output word OUT2 and OUT3 (parameter word)
For command 4000
hex
the parameters must be specified in OUT2 and OUT3. This parameter word is only evaluated for
this command.
12.3 Parameters for configuration
The values in bold are default settings.
Bit 15:
Bit 8:
Bit 3 to bit 0:
OUT2 and OUT3
Bit 1514131211109876543210
Assignment 1000000Filter00000Characteristic
Bit 15 The set bit ensures that the relevant channel is configured.
In the event that only one channel is used and there is no jumper supply at the other channel due to missing
wire jumpers, the configuration is acknowledged negatively in the status word. In this case, set bit 15 of the
configuration word of the unused channel to 0 to remedy the situation.
Filter Selection of mean value generation. After every conversion, the measured value is saved in a mean value
memory via which the mean value is generated. The memory size can be selected with the filter option. E.g.,
for a 16-sample mean value, the mean value is generated using the last 16 measured values.
Character-
istic
Depending on the characteristic in relation to the available jumper supply, the terminal calculates the required
gain for the configured input and thus has the best possible resolution in the unipolar and bipolar area.
If in the unipolar area the strain gauge is supplied with a load greater than 130% or a negative load, the
jumper detuning is outside the measuring range and an error is triggered.
If in the bipolar area the strain gauge is supplied with a load greater than 130% in the positive or negative
direction, the jumper detuning is outside the measuring range and an error is triggered.
If invalid parameters are specified in the parameter word, the command will not be executed. The command is
acknowledged in the input words with the error bit set.
Code Configure
dec bin
0 0 Channel is not configured
1 1 Channel is configured
Code Filter
dec bin
00No mean value
1 1 16-sample mean value
Code Characteristic
dec bin
0 000 +1 mV/V
1 001 ±1 mV/V
2 010 +2 mV/V
3011±2 mV/V
4 100 +3 mV/V
5 101 ±3 mV/V
6 110 +4 mV/V
7 111 ±4 mV/V

2878735

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Controllers IB IL SGI 2/F- 2MBD-PAC
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet