IB IL SGI 2/F ...
7210_en_02 PHOENIX CONTACT 7
4 Local diagnostic and status indicators and terminal point assignment
Figure 1 Terminal with an appropriate connector
4.1 Local diagnostic and status indicators
4.2 Function identification
Green
2 Mbps: White stripe in the vicinity of the D LED
4.3 Terminal point assignment
Des. Color Meaning
D Green Diagnostics
TR Green PCP active
CH1 Green Diagnostic indicator of channel 1
ON: Channel 1 OK
OFF: Channel 1 not connected or not supplied
or open circuit
CH2 Green Diagnostic indicator of channel 2
ON: Channel 2 OK
OFF: Channel 2 not connected or not supplied
or open circuit
TR
7210A002
SGI 2/F
C
H
2
C
H
1
D
SGI 2/F
CH1
CH2
TR
D
12
1
2
3
4
1
2
3
4
1.1
1.2
1.3
1.4
2.1
2.2
2.3
2.4
12
1
2
3
4
1
2
3
4
1.1
1.2
1.3
1.4
2.1
2.2
2.3
2.4
1, 3 2, 4
Terminal
points
Signal Assignment
Connectors 1 and 3
1.1 +U
V
Jumper
supply U
V
2.1 GND
Uv
1.2 +U
0
Jumper voltage U
0
2.2 -U
0
1.3 +U
d
Jumper difference U
d
2.3 -U
d
1.4, 2.4 FE Shielding
Connectors 2 and 4
1.1 5 V Optional voltages to supply the
jumper
2.1 3.3 V
1.2, 2.2 +U
V
Routing of the selected supply
voltage to the "Jumper
supply U
V
"
connection on connector 1 or 3
1.3, 2.3 Not used
1.4, 2.4 FE Shielding
Connect the terminal point of the selected
voltage for the jumper supply to terminal point
+U
V
on connector 2 (or 4). Terminal points +U
V
on slot 2 (or 4) are connected internally to
terminal point +U
V
on slot 1 (or 3) (see
Figure 2). Therefore, the selected voltage at
+U
V
is available on slot 1 (or 3) (see also
"Connection examples" on page 10).
IB IL SGI 2/F ...
7210_en_02 PHOENIX CONTACT 8
5 Internal circuit diagram
Figure 2 Internal circuit diagram
Key:
Local bus
U
L+
U
ANA
U
L-
+24V(U )
M
+24V(U)
S
REF
MUX
Supervisor
µC
SRE 1
OPC
Level Adaptation 3V/5V
24 V
+5 V
+3,3 V
7210B003
AGND
AGND
AGND
Protocol chip Analog/digital converter
Register expansion Reference voltage
Level adaptation Multiplexer
Hardware monitoring Amplifier
Microcontroller
DC/DC converter
with electrical isolation
Optocoupler
OPC
S R E 1
R E F
Level Adaptation 3V/5V
M U X
S u p e r v i s o r
µ C
x x x
X X X
Other symbols used are explained in the
IL SYS INST UM E user manual.
IB IL SGI 2/F ...
7210_en_02 PHOENIX CONTACT 9
6 Electrical isolation
Figure 3 Electrical isolation of the individual function
areas
7 Installation instructions
High current flowing through potential jumpers U
M
and U
S
leads to a temperature rise in the potential jumpers and
inside the terminal. Observe the following instructions to
keep the current flowing through the potential jumpers of
the analog terminals as low as possible:
8 Connection notes
Connecting the strain gauges
Shield connection
Unused channels
For unused channels, follow the instructions for
parameterization (see notes on bit 15 on page 15).
Create a separate main circuit for the
analog terminals
If this is not possible in your application and if
you are using analog terminals in a main circuit
together with other terminals, place the analog
terminals after all the other terminals at the end
of the main circuit.
Connect the strain gauges using shielded
twisted pair cables.
Only connect the shielding at one point,
preferably to the terminal. If the shield is
securely connected to the sensor, insulate the
shield on the terminal side.