28
COMMERCIAL TEMPERATURE RANGE
IDT72V71643 3.3V TIME SLOT INTERCHANGE
DIGITAL SWITCH 4,096 x 4,096
Symbol Parameter Min. Typ. Max. Units
tSIS RX Setup Time 5 ⎯⎯ns
tSIH RX Hold Time 10 ⎯⎯ns
tSOD TX Delay – Active to Active ⎯⎯30 ns
tDZ
(1)
TX Delay – Active to High-Z ⎯⎯30 ns
tZD
(1)
TX Delay – High-Z to Active ⎯⎯30 ns
tODE
(1)
Output Driver Enable (ODE) Delay ⎯⎯30 ns
tOEIE Output Enable Indicator (OEI) Enable ⎯⎯40 ns
tOEID Output Enable Indicator (OEI) Disable ⎯⎯25 ns
tRZ Active to High-Z on Master Reset ⎯⎯30 ns
tZR High-Z to Active on Master Reset ⎯⎯30 ns
t
Rs Reset pulse width 100 ⎯⎯ns
AC ELECTRICAL CHARACTERISTICS
(1)
⎯ SERIAL STREAM (ST-BUS
®
and GCI)
NOTE:
1. High-Impedance is measured by pulling to the appropriate rail with R
L
(1KΩ), with timing corrected to cancel time taken to discharge C
L
(150 pF).