OBID
®
classic-pro Installation ID CPR.M02
FEIG ELECTRONIC GmbH Page 25 of 42 M21001-3de-ID-B.doc
E N G L I S H
Contents
6. Safety Instructions / Warning - Read before start-up ! 26
7. Performance Characteristics of the ID CPR.M02 Reader 27
7.1. Performance Characteristics ...........................................................................................27
7.2. Available module and antenna types ..............................................................................27
7.3. Scope of delivery...............................................................................................................27
8. Installation and wiring 28
8.1. Dimensions........................................................................................................................28
8.2. Wiring .................................................................................................................................29
8.2.1. Supply voltage .............................................................................................................30
8.2.2. RS232 interface...........................................................................................................31
8.2.3. Data/Clock interface ....................................................................................................32
8.2.4. Connection of an external Antenna (ID CPR.M02.VP/AB-BA / -CA)...........................33
8.2.5. Optional Module ID SAM.M02 .....................................................................................34
8.3. Display elements...............................................................................................................35
8.4. Operating elements...........................................................................................................36
8.4.1. Operating/Programming Mode: Jumper J1..................................................................36
8.4.2. Retuning the internal antenna (ID CPR.M02.VP/AB-B / -C)........................................37
8.5. Installation notes...............................................................................................................39
8.5.1. Metallic surroundings...................................................................................................39
8.5.2. EMC effects on cables.................................................................................................39
8.5.3. EMC effects from magnetic fields................................................................................40
9. Radio Approvals 41
9.1. Europe (CE)........................................................................................................................41
9.2. USA (FCC)..........................................................................................................................41
10. Technical Data 42
OBID
®
classic-pro Installation ID CPR.M02
FEIG ELECTRONIC GmbH Page 26 of 42 M21001-3de-ID-B.doc
E N G L I S H
6. Safety Instructions / Warning - Read before start-up !
The device has to be used only for the purpose designed by the manufacturer.
The operation manual has to be stored available at any time and has to be handed over to
each user.
Unauthorized changes and the use of spare parts and additional devices which have not been
sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such
measures will lead to exclusion of any liability by the manufacturer.
The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid
for the device. The manufacturer is not legally responsible for incorrect, unsuitable manual or
automatical setting of parameters for a device or the incorrect application of a device.
Repairs can only be executed by the manufacturer.
Installation-, operation- and maintenance procedures should only be carried out by qualified
personnel.
Before opening the device, the power supply must always be interrupted. Make sure that the
device is without voltage by measuring. CAUTION! The fading of an operation control (LED) is
no indicator for an interrupted power supply or the device being without voltage!
Works at the device and its installation have to be executed according to the national legal
requirements and local prescriptions.
When working on devices the valid safety regulations must be observed.
OBID
®
classic-pro Installation ID CPR.M02
FEIG ELECTRONIC GmbH Page 27 of 42 M21001-3de-ID-B.doc
E N G L I S H
7. Performance Characteristics of the ID CPR.M02 Reader
7.1. Performance Characteristics
The ID CPR.M02 Reader Module is designed for reading and writing passive transponders having
an operating frequency of 13.56 MHz. It is suitable for any application in which short read ranges
and small reader dimensions are required.
7.2. Available module and antenna types
The following module types are currently available:
Modul Type Power Supply Antenna RS232-TTL
Interface
Data-/Clock
Interface
ID CPR.M02.VP/AB-B
internal
ID CPR.M02.VP/AB-BA
external
4.800, 9.600,
19.200, 38.400,
Baud
ID CPR.M02.VP/AB-C
internal
ID CPR.M02.VP/AB-CA
5 V DC
external
4.800, 9.600,
19.200, 38.400,
57.600, 115.200,
230.400 Baud
Mag. Stripe
Wiegand
The following antenna types are currently available:
Antenna Description
ID ISC.ANT100/100-A
PCB- Antenna, 50, 100mm x 100mm
ID ISC.ANT40/30-A
PCB- Antenna, 50, 40mm x 30mm
7.3. Scope of delivery
The following components are included:
Modul Type Included
ID CPR.M02.VP/AB-B 1 x Reader Module ID CPR.M02.VP/AB-B
ID CPR.M02.VP/AB-BA 1 x Reader Module ID CPR.M02.VP/AB-BA
ID CPR.M02.VP/AB-C 1 x Reader Module ID CPR.M02.VP/AB-C
ID CPR.M02.VP/AB-CA 1 x Reader Module ID CPR.M02.VP/AB-CA