OBID
®
classic-pro Installation ID CPR.M02
FEIG ELECTRONIC GmbH Page 40 of 42 M21001-3de-ID-B.doc
E N G L I S H
8.5.3. EMC effects from magnetic fields
Since in this type of RFID-Technology the communication between the reader and transponder
takes place by modulation of a magnetic field, alternating magnetic fields in the vicinity of the an-
tenna can have a negative impact on its function.
Sources of such magnetic interference fields include coils within a primary or secondary switching
power supply.
When determining the position of the reader and antenna within a device, check the device for any
possible sources of interference as described above. If necessary, use shielding to suppress such
interference.
OBID
®
classic-pro Installation ID CPR.M02
FEIG ELECTRONIC GmbH Page 41 of 42 M21001-3de-ID-B.doc
E N G L I S H
9. Radio Approvals
9.1. Europe (CE)
When used according to regulation, this radio equipment conforms with the basic requirements of
Article 3 and the other relevant provisions of the R&TTE Guideline 1999/E6 dated March 99.
Equipment Classification according ETSI EN 300 330: Class 2
9.2. USA (FCC)
FCC ID: PJMCPRM02
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
Unauthorized modifications may void the authority granted under Federal communica-
tions Commission Rules permitting the operation of this device.
This device is labeled with an FCC ID number.
If this label is not visible when installed in an end device, the outside of the device MUST
also display a label referring to the enclosed module.
Wording on the label similar to the following shall be used:
This device contains transmitter module FCC ID PJMCPRM02
At the time of this printing, the antennas listed below were the only antennas approved for
use with the ID CPR.M02 module. Use of other antennas must be approved by
FEIG ELECTRONIC GmbH.
Antennas approved: ID ISC.ANT100100; ID ISC.ANT4030
OBID
®
classic-pro Installation ID CPR.M02
FEIG ELECTRONIC GmbH Page 42 of 42 M21001-3de-ID-B.doc
E N G L I S H
10. Technical Data
Dimensions ( W x H x D )
50 mm x 50 mm x 14 mm
Connector
10 pol. Pin-Connector (grid dim. 2,54 mm)
Supply voltage 5 V DC ± 5% ripple
0...250 kHz < 10 mVpp
ab 250 kHz < 0,1 mVpp
Power Consumption
max. 1,5 W
Operating Frequency
13.56 MHz
RF Transmitting Power 250 mW ± 2 dB
Antenna:
ID CPR.M02.VP/AB-B / -C
ID CPR.M02.VP/AB-BA / -CA
Internal, 48 mm x 48 mm
External (separate 2 pol. Pin-Connector)
RS232-TTL Interface:
ID CPR.M02.VP/AB-B / -BA
ID CPR.M02.VP/AB-C / -CA
4.800 to 38.400 Baud
4.800 to 230.400 Baud
Daten-/Takt Interface
Magnet Stripe Emulation
Wiegand Emulation
EEPROM (for parameters)
1 kB (10,000 write cycles)
FLASH
64 kB (software update on interface possible)
Supported Transponders
read and write
ISO14443-A compatible
(e. g. mifare, mifare Ultra Light, my-d proximity)
ISO14443-B compatible
ISO15693 compatible
(e. g. ICode SLI, Tag-It HFI, my-d vicinity, STM
LRI512)
ICode 1 (optional)
Security Function (optional)
SAM (Security Access Module),
e.g. for my-d vicinity and my-d proximity
Optical Indicators
LED green: running;
LED red: Transponder detected
Temperature Range
Operating
Storage
-20°C to +70°C
-40°C to +85°C
Radio Approval
Europe
USA
EN 300 330
FCC 47 CFR Part 15
EMC
EN 301 489
Safety
EN 60950

2873.000.00

Mfr. #:
Manufacturer:
Description:
RFID READER R/W 13.56MHZ MOD
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet