4 www.ixysic.com R02
1.3 Absolute Maximum Ratings
Absolute maximum electrical ratings are over the
operating temperature range.
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
1.4 Recommended Operating Conditions
1
V
PV
applied only when programming the EEPROM.
1.5 ESD Ratings
1.6 General Conditions for Electrical Characteristics
Typical values are characteristic of the device and are
the result of engineering evaluations. They are
provided for informational purposes only, and are not
guaranteed by production testing.
Unless otherwise specified: Specifications cover the
operating temperature range T
A
=-40C to +85C, the
supply voltage range V
DD
= 2.5V to 5.5V and
V
PV
= 0V (or pin PV is open circuit). For testing
purposes V
DD
= 5V, the logic low input voltage is 0V
DC
and the logic high input voltage is 5V
DC
.
Parameter Minimum Maximum Unit
Supply Voltage, V
DD
-V
SS
-0.3 + 6 V
Pins DA, CLK, and X1 Voltage
V
SS
-0.3 V
DD
+ 0.3
V
Pin PV Voltage
V
SS
-0.3
7.5 V
PV Pulse Width, t
PV
-80ms
Operating Temperature, T
A
-40 +85 C
Storage temperature, T
STG
-55 +150 C
Parameter Symbol Minimum Typical Maximum Unit
Supply Voltage
V
DD
2.5 3.3 5.5 V
X1 Voltage
V
X1
--3.6V
PV Voltage
1
V
PV
66.57 V
PV Pulse Width
t
PV
40 50 80 ms
Operating Temperature
Normal Operation and
Shift Register Mode
T
A
-40 - +85
°C
Programming Modes +20 - +30
Parameter Symbol Conditions Rating Unit
Human Body Model HBM EIA/JESD22-A114-D
All pins except X1 +2
kV
Pin X1 +
1
Charged Device Model CDM EIA/JESD22-C101-C
All pins except X1 +
500
V
Pin X1 +
250