HVLED805 Electrical characteristics
Doc ID 18077 Rev 1 5/29
3 Electrical characteristics
T
J
= -25 to 125 °C, Vcc=14 V; unless otherwise specified.
Table 4. Electrical characteristics
Symbol Parameter Test condition Min. Typ. Max. Unit
Power section
V
(BR)DSS
Drain-source breakdown I
D
< 100 µA; Tj = 25 °C 800 V
I
DSS
Off state drain current
V
DS
= 750V; Tj = 125 °C
(See Figure 4 and note)
80 µA
R
DS(on)
Drain-source ON-state resistance
Id=250 mA; Tj = 25 °C 11 14
Ω
Id=250 mA; Tj = 125 °C 28
C
oss
Effective (energy-related) output capacitance (See Figure 3)
High-voltage start-up generator
V
Start
Min. drain start voltage I
charge
< 100µA 40 50 60 V
I
charge
Vcc startup charge current
V
DRAIN
> V
Start
; Vcc<Vcc
On,
Tj = 25 °C
45.57
mA
V
DRAIN
> V
Start
; Vcc<Vcc
On
+/-10%
V
CCrestart
Vcc restart voltage
(Vcc falling)
(1)
9.5 10.5 11.5
V
After protection tripping 5
Supply voltage
Vcc Operating range After turn-on 11.5 23 V
Vcc
On
Turn-on threshold
(1)
12 13 14 V
Vcc
Off
Turn-off threshold
(1)
91011V
V
Z
Zener voltage Icc = 20mA 23 25 27 V
Supply current
Icc
start-up
Start-up current (See Figure 5) 200 300 µA
Iq Quiescent current (See Figure 6)11.4mA
Icc Operating supply current @ 50 kHz (See Figure 7)1.41.7mA
Iq
(fault)
Fault quiescent current
During hiccup and brownout
(See Figure 8)
250 350 µA
Start-up timer
T
RESTART
Start timer period 105 140 175 µs
T
START
Restart timer period during burst mode 420 500 700 µs
Demagnetization detector
I
DMGb
Input bias current V
DMG
= 0.1 to 3V 0.1 1 µA