33
Number
Pin Name
Pull-up
Type
Description
Analog input channel 0, 0-1.2V range, needs to be
pulled down to AVSS if unused
Analog input channel 1, 0-1.2V range, needs to be
pulled down to AVSS if unused
Unbuffered analog reference voltage output (0.6V),
capacitor needs to be connected.
Analog reference voltage output (0.6V)
Compressor single shunt current sensing OP amp
input (-)
Compressor single shunt current sensing OP amp
input (+)
Compressor single shunt current sensing OP amp
output
AC input voltage sensing OP amp input (-)
AC input voltage sensing OP amp input (+)
AC input voltage sensing OP amp output
PFC shunt current sensing OP amp output
PFC shunt current sensing OP amp input (+)
PFC shunt current sensing OP amp input (-)
Compressor PWM shutdown input, 2-μsec digital
filter, configurable either high or low true.
Compressor PWM gate drive for phase W low side,
configurable either high or low true
Compressor PWM gate drive for phase W high side,
configurable either high or low true
Compressor PWM gate drive for phase V low side,
configurable either high or low true
Compressor PWM gate drive for phase V high side,
configurable either high or low true
Compressor PWM gate drive for phase U low side,
configurable either high or low true
Compressor PWM gate drive for phase U high side,
configurable either high or low true
Discrete programmable I/O or INT2 digital input