REV. A
ADF4210/ADF4211/ADF4212/ADF4213
–14–
Table V. RF R Latch Map
DB20 DB19 DB18 DB17 DB16 DB15 DB14 DB13 DB12 DB11 DB10 DB9 DB8 DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
C2 (1)
C1 (0)R1R2R3R4R5R6R7R8R9R10R11R12R13R14P9P10
CONTROL
BITS
15-BIT REFERENCE COUNTER
DB21
RF PD
POLARITY
THREE-STATE
CP
RF
LOCK DETECT
RF F
O
RF R COUNTER LATCH
DB23 DB22
RF
CP2
RF
CP1
RF
CP0
RF CP CURRENT
SETTING
P11P12
R15 R14 R13 .......... R3 R2 R1 DIVIDE RATIO
000..........0011
000..........0102
000..........0113
000..........1004
.................
.................
.................
1 1 1 .......... 1 0 0 32764
1 1 1 .......... 1 0 1 32765
1 1 1 .......... 1 1 0 32766
1 1 1 .......... 1 1 1 32767
0 NEGATIVE
1 POSITIVE
0000LOGIC LOW STATE
0001IF ANALOG LOCK DETECT
0010IF REFERENCE DIVIDER OUTPUT
0011IF N DIVIDER OUTPUT
0100RF ANALOG LOCK DETECT
0101RF/IF ANALOG LOCK DETECT
0110IF DIGITAL LOCK DETECT
0111LOGIC HIGH STATE
1000RF REFERENCE DIVIDER OUTPUT
1001RF N DIVIDER OUTPUT
1010THREE-STATE OUTPUT
1011IF COUNTER RESET
1100RF DIGITAL LOCK DETECT
1101RF/IF DIGITAL LOCK DETECT
1110RF COUNTER RESET
1111IF AND RF COUNTER RESET
0 NORMAL
1 THREE-STATE
RF CP2 RF CP1 RF CP0 1.5k 2.7k 5.6k
0001.1250.6250.301
0012.251.250.602
0103.3751.8750.904
0 1 1 4.5 2.5 1.205
1005.6253.1251.506
1016.753.751.808
1107.7875 4.375 2.109
1 1 1 9.0 5.0 2.411
I
CP
(mA)
R15
P9 RF PD POLARITY
P10 CHARGE PUMP OUTPUT
MUXOUTP11 P4 P3
P12
FROM IF R LATCH