ADuM3440/ADuM3441/ADuM3442 Data Sheet
Rev. D | Page 10 of 24
PACKAGE CHARACTERISTICS
Table 4.
Parameter Symbol Min Typ Max Unit Test Conditions
Resistance (Input to Output)
1
R
I-O
10
12
Capacitance (Input to Output)
1
C
I-O
2.2 pF f = 1 MHz
Input Capacitance
2
C
I
4.0 pF
IC Junction-to-Case Thermal Resistance, Side 1 θ
JCI
33 °C/W Thermocouple located at
center of package underside
IC Junction-to-Case Thermal Resistance, Side 2 θ
JCO
28 °C/W
1
The device is considered a 2-terminal device; Pin 1 through Pin 8 are shorted together and Pin 9 through Pin 16 are shorted together.
2
Input capacitance is from any input data pin to ground.
REGULATORY INFORMATION
The ADuM344x is approved by the organizations listed in Table 5. Refer to Table 10 and the Insulation Lifetime section for details
regarding recommended maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 5.
UL CSA VDE
Recognized under
1577 component recognition program
1
Approved under
CSA Component Acceptance Notice #5A
Certified according to
DIN V VDE V 0884-10 (VDE V 0884-10):2006-12
2
Single protection,
2500 V rms isolation voltage
Basic insulation per CSA 60950-1-03 and
IEC 60950-1, 800 V rms (1131 V peak)
maximum working voltage
Reinforced insulation, 560 V peak
Reinforced insulation per CSA 60950-1-03
and IEC 60950-1, 400 V rms (566 V peak)
maximum working voltage
File E214100 File 205078 File 2471900-4880-0001
1
In accordance with UL 1577, each ADuM344x is proof tested by applying an insulation test voltage ≥3000 V rms for 1 sec (current leakage detection limit = 5 µA).
2
In accordance with DIN V VDE V 0884-10, each ADuM344x is proof tested by applying an insulation test voltage ≥1050 V peak for 1 sec (partial discharge detection
limit = 5 pC). An asterisk (*) marking branded on the component designates DIN V VDE V 0884-10
approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter Symbol Value Unit Conditions
Rated Dielectric Insulation Voltage 2500 V rms 1-minute duration
Minimum External Air Gap (Clearance) L(I01) 7.7 min mm Measured from input terminals to output terminals,
shortest distance through air
Minimum External Tracking (Creepage) L(I02) 8.1 min mm Measured from input terminals to output terminals,
shortest distance path along body
Minimum Internal Gap (Internal Clearance) 0.017 min mm Insulation distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >175 V DIN IEC 112/VDE 0303 Part 1
Isolation Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1)
Data Sheet ADuM3440/ADuM3441/ADuM3442
Rev. D | Page 11 of 24
DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS
These isolators are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by
protective circuits. The asterisk (*) marking on packages denotes DIN V VDE V 0884-10 approval.
Table 7.
Description Conditions Symbol Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage 150 V rms I to IV
For Rated Mains Voltage ≤ 300 V rms I to III
For Rated Mains Voltage ≤ 400 V rms I to II
Climatic Classification 40/105/21
Pollution Degree per DIN VDE 0110, Table 1 2
Maximum Working Insulation Voltage V
IORM
560 V peak
Input-to-Output Test Voltage, Method B1 V
IORM
× 1.875 = V
PR
, 100% production test, t
m
= 1 sec,
partial discharge < 5 pC
V
PR
1050 V peak
Input-to-Output Test Voltage, Method A V
IORM
× 1.6 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC V
PR
After Environmental Tests Subgroup 1 896 V peak
After Input and/or Safety Test
Subgroup 2 and Subgroup 3
V
IORM
× 1.2 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC 672 V peak
Highest Allowable Overvoltage Transient overvoltage, t
TR
= 10 seconds V
TR
4000 V peak
Safety-Limiting Values Maximum value allowed in the event of a failure
(see Figure 4)
Case Temperature T
S
150 °C
Side 1 Current I
S1
265 mA
Side 2 Current I
S2
335 mA
Insulation Resistance at T
S
V
IO
= 500 V R
S
>10
9
CASE TEMPERATURE (°C)
SAFETY-LIMITING CURRENT (mA)
0
0
350
300
250
200
150
100
50
50 100 150 200
SIDE #1
SIDE #2
06837-004
Figure 4. Thermal Derating Curve, Dependence of Safety-Limiting Values
with Case Temperature per DIN V VDE V 0884-10
RECOMMENDED OPERATING CONDITIONS
Table 8.
Parameter Rating
Operating Temperature Range, T
A
−40°C to +105°C
Supply Voltage Range, V
DD1
, V
DD2
1
3.0 V to 5.5 V
Input Signal Rise and Fall Time 1.0 ms
1
All voltages are relative to their respective ground. See the DC Correctness
and Magnetic Field Immunity section for information on immunity to external
magnetic fields.
ADuM3440/ADuM3441/ADuM3442 Data Sheet
Rev. D | Page 12 of 24
ABSOLUTE MAXIMUM RATINGS
Ambient temperature = 25°C, unless otherwise noted.
Table 9.
Parameter Rating
Storage Temperature Range (T
ST
) −65°C to +150°C
Ambient Operating Temperature Range (T
A
) −40°C to +105°C
Supply Voltages (V
DD1
, V
DD2
)
1
−0.5 V to +7.0 V
Input Voltage (V
IA
, V
IB
, V
IC
, V
ID
, V
E1
, V
E2
)
1, 2
−0.5 V to V
DD1
+ 0.5 V
Output Voltage (V
OA
, V
OB
, V
OC
, V
OD
)
1, 2
−0.5 V to V
DDO
+ 0.5 V
Average Output Current per Pin
3
Side 1 (I
O1
) −18 mA to +18 mA
Side 2 (I
O2
) −22 mA to +22 mA
Common-Mode Transients (CM
H
, CM
L
)
4
−100 kV/µs to
+100 kV/µs
1
All voltages are relative to their respective ground.
2
V
DDI
and V
DDO
refer to the supply voltages on the input and output sides of a
given channel, respectively. See the PC Board Layout section.
3
See Figure 4 for maximum rated current values for various temperatures.
4
Refers to common-mode transients across the insulation barrier. Common-
mode transients exceeding the Absolute Maximum Ratings can cause latch-
up or permanent damage.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
ESD CAUTION
Table 10. Maximum Continuous Working Voltage
1
Parameter
Max
Unit
Constraint
AC Voltage, Bipolar Waveform 565 V peak 50-year minimum lifetime
AC Voltage, Unipolar Waveform
Basic Insulation 1131 V peak Maximum approved working voltage per IEC 60950-1
Reinforced Insulation 560 V peak Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
DC Voltage
Basic Insulation 1131 V peak Maximum approved working voltage per IEC 60950-1
Reinforced Insulation 560 V peak Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
1
Refers to continuous voltage magnitude imposed across the isolation barrier. See the Insulation Lifetime section for more details.
Table 11. Truth Table (Positive Logic)
V
IX
Input
1
V
EX
Input
2
V
DDI
State
1
V
DDO
State
1
V
OX
Output
1
Notes
H H or NC Powered Powered H
L H or NC Powered Powered L
X L Powered Powered Z
X H or NC Unpowered Powered H Outputs return to the input state within 1 µs of V
DDI
power restoration.
X L Unpowered Powered Z
X X Powered Unpowered
Indeterminate Outputs return to the input state within 1 µs of V
DDO
power
restoration if V
EX
state is H or NC. Outputs return to high impedance
state within 8 ns of V
DDO
power restoration if V
EX
state is L.
1
V
IX
and V
OX
refer to the input and output signals of a given channel (A, B, C, or D). V
EX
refers to the output enable signal on the same side as the V
OX
outputs. V
DDI
and
V
DDO
refer to the supply voltages on the input and output sides of the given channel, respectively.
2
In noisy environments, connecting V
EX
to an external logic high or low is recommended.

ADUM3441CRWZ-RL

Mfr. #:
Manufacturer:
Analog Devices Inc.
Description:
Digital Isolators Quad-CH High Speed Digital
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet