ACPL-M71U-000E

ACPL-M71U and ACPL-M72U
Wide Operating Temperature, High Speed, Low Power
Digital Optocouplers with R
2
Coupler™ Isolation
Data Sheet
CAUTION: It is advised that normal static precautions be taken in handling and assembly
of this component to prevent damage and/or degradation which may be induced by ESD.
Features
5 V CMOS compatible
Common-Mode Rejection 40kV/s @ V
CM
=1000V:
Wide Industrial temperature range: –40°C to 125°C
Low propagation delay :
High Speed ACPL-M71U: 26ns @ I
F
= 10 mA
(Typical)
Low Power ACPL-M72U: 60ns @ I
F
= 4 mA (Typical)
Worldwide safety approval:
UL 1577 recognized, 3750 Vrms / 1 min
– CSA approved
IEC/EN/DIN EN 60747-5-5
Applications
Industrial CANBus communications interface
Industrial isolated high speed gate drivers for IGBTs
and Power MOSFETs
High temperature digital signal isolation
Microcontroller interface
Digital isolation for A/D and D/A conversion
Description
The Avago ACPL-M71U and ACPL-M72U are high tem-
perature, digital CMOS optocouplers in SOIC-5 packages.
These optocouplers use the latest CMOS IC technology
to achieve outstanding performance and very low power
consumption. All devices operate over the –40°C to 125 °C
temperature range.
The ACPL-M71U uses a high speed LED, and the
ACPL-M72U uses a low current LED for lower power dis-
sipation. The high speed ACPL-M71U featuring a 35 ns
maximum propagation delay (I
F
=10 mA). The ACPL-M72U
optocoupler features very low power. With a low 4 mA
LED drive current, ACPL-M72U typical propagation delay
is 60 ns.
Each digital optocoupler has a CMOS detector IC, an in-
tegrated photodiode, a high speed transimpedance
ampli er, and a voltage comparator with an output
driver.
Avago R
2
Coupler isolation products provide the rein-
forced insulation and reliability needed for critical in high
temperature industrial applications
Functional Block Diagram
Note: A 0.1 F bypass capacitor must be connected between pins 4 and 6.
1
3
6
4
5
Anode
Cathode
Vdd
Gnd
V
o
ACPL-M71U/ACPL-M72U
Truth Table
LED Output (V
O
)
OFF H
ON L
2
Ordering Information
Part Number
Option
Package Surface Mount Tape & Reel Quantity(RoHS) Compliant
ACPL-M71U -000E SO-5 X 100 per tube
-500E X X 1500 per reel
ACPL-M72U -000E SO-5 X 100 per tube
-500E X X 1500 per reel
To order, choose a part number from the part number column and combine with the desired option from the option
column to form an order entry.
For example, the part number ACPL-M71U-500E describes a device with a surface mount SOIC-5 package; delivered in
Tape and Reel with 1500 parts per reel; and full RoHS compliance.
Option datasheets are available. Contact your Avago sales representative or authorized distributor for information.
Package Dimensions
ACPL-M71U / ACPL-M72U (JEDEC MO-155 Package)
MXXX
XXX
7.0 ± 0.2
(0.276 ± 0.008)
2.5 ± 0.1
(0.098 ± 0.004)
0.102 ± 0.102
(0.004 ± 0.004)
4.4 ± 0.1
(0.173 ± 0.004)
1.27
(0.050)
BSC
0.15 ± 0.025
(0.006 ± 0.001)
0.71
(0.028)
MIN
0.4 ± 0.05
(0.016 ± 0.002)
3.6 ± 0.1*
(0.142 ± 0.004)
Dimensions in millimeters (inches).
Note: Foating Lead Protrusion is 0.15 mm (6 mils) max.
* Maximum Mold ash on each side is 0.15 mm (0.006).
7° MAX.
MAX. LEAD COPLANARITY
= 0.102 (0.004)
8.27
(0.325)
1.8
(0.072)
2.5
(0.10)
1.3
(0.05)
0.5
(0.02)
4.4
(0.17)
LAND PATTERN RECOMMENDATION
0.3
(0.01)
ROHS-COMPLIANCE
INDICATOR
PART NUMBER
DATE CODE
3
Insulation and Safety Related Speci cations
Parameter Symbol Value Units Conditions
Minimum External Air
Gap (Clearance)
L(I01) >5 mm Measured from input terminals to output terminals,
shortest distance through air.
Minimum External
Tracking (Creepage)
L(I02) >5 mm Measured from input terminals to output terminals,
shortest distance path along body.
Minimum Internal Plastic
Gap (Internal Clearance)
0.08 mm Insulation thickness between emitter and detector;
also known as distance through insulation.
Tracking Resistance
(Comparative Tracking Index)
CTI >175 Volts DIN IEC 112/VDE 0303 Part 1
Isolation Group IIIa Material Group (DIN VDE 0109)
IEC/EN/DIN EN 60747-5-5 Insulation Related Characteristics
Description Symbol
ACPL-M71U/
ACPL-M72U Units
Maximum Working Insulation Voltage V
IORM
567 V
PEAK
Input to Output Test Voltage, Method b
V
IORM
x 1.875 = V
PR
, 100% Production
Test with t
m
= 1 sec, Partial Discharge < 5 pC
V
PR
1063 V
PEAK
Input to Output Test Voltage, Method a
V
IORM
x 1.6 = V
PR
, Type and Sample Test,
t
m
= 10 sec, Partial Discharge < 5 pC
V
PR
907 V
PEAK
Highest Allowable Overvoltage
(Transient Overvoltage, t
ini
= 60 sec)
V
IOTM
6000 V
PEAK
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Thermal Derating curve, Figure 11.)
Case Temperature T
s
175 °C
Input Current I
s, INPUT
150 mA
Output Power P
s,OUTPUT
600 mW
Insulation Resistance at T
S
, V
IO
= 500 V R
IO
≥10
9
Recommended Pb-Free IR Pro le
Recommended re ow condition as per JEDEC Standard, J-STD-020 (latest revision).
Note: Non-halide  ux should be used.
Regulatory Information
The ACPL-M71U and ACPL-M72U are approved by the following organizations:
UL
Approved under UL 1577, component recognition program up to V
ISO
= 3750 V
RMS
expected prior to product release.
CSA
Approved under CSA Component Acceptance Notice #5.
IEC/EN/DIN EN 60747-5-5

ACPL-M71U-000E

Mfr. #:
Manufacturer:
Broadcom / Avago
Description:
High Speed Optocouplers Optocoupler
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union