KMA199 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2011. All rights reserved.
Product data sheet Rev. 2 — 7 December 2011 7 of 36
NXP Semiconductors
KMA199
Programmable angle sensor
Table 4 shows the resulting output voltage depending on the error case and the load
resistance.
7.4 Low supply voltage detection
If the supply voltage is below the switch-off threshold voltage, a status bit is set.
Table 5
describes the behavior of the analog output at different supply voltages.
Fig 4. Equivalent output circuit in case of a power-loss condition
Table 4. Power-loss behavior
Load resistance Supply voltage lost Ground lost
R
L
>5k V
O
4%V
DD
V
O
96 %V
DD
Table 5. Supply voltage behavior
Voltage range Description Analog output
0Vto 1.5 V the output drives an active LOW, but the
switches of the power-loss detection circuits
are not fully opened and set the output to a
level between ground and half the supply
voltage
actively driven output to a
voltage level between ground
and half the supply voltage
1.5 V to V
POR
all modules begin to work and the power-on
reset is active
diagnostics at LOW level
V
POR
to V
th(on)
or
V
th(off)
all modules begin to work and the digital part is
initialized
EEPROM defined diagnostic
level
V
th(on)
or V
th(off)
to
4.5 V
analog output is switched on after power-on
time and represents the measured angle
analog output of the
measured angle without the
specified accuracy
4.5 V to 5.5 V normal operation where the sensor works with
the specified accuracy
analog output of the
measured angle
KMA199 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2011. All rights reserved.
Product data sheet Rev. 2 — 7 December 2011 8 of 36
NXP Semiconductors
KMA199
Programmable angle sensor
8. Limiting values
[1] Time until sensor environment is initialized.
[2] The maximum value of the output voltage is 5.7 V.
9. Recommended operating conditions
[1] Normal operating mode.
[2] Between ground and analog output, as close as possible to the package for improved electromagnetic
immunity.
[3] Between ground and supply voltage, as close as possible to the package and with a low equivalent series
resistance.
[4] Power-loss detection is only possible with a load resistance within the specified range connected to the
supply or ground line.
10. Thermal characteristics
Table 6. Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134).
Symbol Parameter Conditions Min Max Unit
V
DD
supply voltage 0.3 +5.7 V
t
init
<200h
[1]
-6.0 V
V
O
output voltage
[2]
0.3 V
DD
+0.3 V
I
r
reverse current T
amb
<70C-150mA
T
amb
ambient temperature 40 +160 C
T
amb(pr)
programming ambient temperature 10 70 C
T
stg
storage temperature 40 +125 C
EEPROM
t
ret(D)
data retention time T
amb
=50C17- year
N
endu(W_ER)
write or erase endurance T
amb(pr)
=70C 100 - cycle
Table 7. Operating conditions
In a homogenous magnetic field.
Symbol Parameter Conditions Min Typ Max Unit
V
DD
supply voltage
[1]
4.5 5.0 5.5 V
T
amb
ambient temperature 40 - +160 C
T
amb(pr)
programming ambient temperature 10 - 70 C
C
L
load capacitance
[2]
0 - 22 nF
C
block
blocking capacitance
[3]
75 - nF
R
L
load resistance
[4]
5- k
H
ext
external magnetic field strength 35 - - kA/m
Table 8. Thermal characteristics
Symbol Parameter Conditions Typ Unit
R
th(j-a)
thermal resistance from junction to
ambient
120 K/W
KMA199 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2011. All rights reserved.
Product data sheet Rev. 2 — 7 December 2011 9 of 36
NXP Semiconductors
KMA199
Programmable angle sensor
11. Characteristics
[1] Normal operating mode.
[2] Without load current at the analog output.
Table 9. Supply current
Characteristics are valid for the operating conditions, as specified in Section 9.
Symbol Parameter Conditions Min Typ Max Unit
I
DD
supply current
[1][2]
5-10mA
Table 10. Power-on reset
Characteristics are valid for the operating conditions, as specified in Section 9
.
Symbol Parameter Conditions Min Typ Max Unit
V
th(on)
switch-on threshold
voltage
analog output switches on, if
V
DD
>V
th(on)
4.00 4.30 4.45 V
V
th(off)
switch-off threshold
voltage
analog output switches off, if
V
DD
<V
th(off)
- 4.20 4.30 V
V
hys
hysteresis voltage V
hys
=V
th(on)
V
th(off)
0.1 - 0.4 V
V
POR
power-on reset voltage IC is initialized 2.4 - 3.3 V
Table 11. System performance
Characteristics are valid for the operating conditions, as specified in Section 9
.
Symbol Parameter Conditions Min Typ Max Unit
res
angle resolution
[1]
- - 0.04 deg
max
maximum angle programmable angular range
for V
(CL)u
V
(CL)l
80 %V
DD
[2]
5 - 180 deg
ref
reference angle programmable zero angle
[2]
0 - 180 deg
V
O(nom)
nominal output voltage at full supply operating range 5 - 95 %V
DD
V
O(udr)
upper diagnostic range
output voltage
[3]
96 - 100 %V
DD
V
O(ldr)
lower diagnostic range
output voltage
[3]
0-4%V
DD
V
(CL)u
upper clamping voltage
[4]
40 - 95 %V
DD
V
(CL)l
lower clamping voltage
[4]
5-30.5%V
DD
V
(CL)
clamping voltage variation deviation from programmed
value
0.3 - +0.3 %V
DD
I
O
output current normal operation mode;
operating as sink or source
--2mA
V
n(o)(RMS)
RMS output noise voltage equivalent power noise
[5]
-0.42.5mV

lin
linearity error temperature range
40 Cto+160C
[5][6]
1.2 - +1.2 deg
temperature range
40 Cto+140C
[5][6]
1 - +1 deg

temp
temperature drift error temperature range
40 Cto+160C
[1][5][6]
[7]
- - 0.8 deg
temperature range
40 Cto+140C
[1][5][6]
[7]
- - 0.65 deg

KMA199,115

Mfr. #:
Manufacturer:
NXP Semiconductors
Description:
Magnetic Sensors Board Mount Hall Effect / Magnetic Sensors Programble Angle Sensor 5V 5mA-10mA
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet