HCPL-2503#500

4
Recommended Pb-Free IR Prole
Solder Reow Temperature Prole
0
TIME (SECONDS)
TEMPERATURE (
°
C)
200
100
50 150100 200 250
300
0
30
SEC.
50 SEC.
30
SEC.
160
°
C
140
°
C
150
°
C
PEAK
TEMP.
245
°
C
PEAK
TEMP.
240
°
C
PEAK
TEMP.
230
°
C
SOLDERING
TIME
200
°
C
PREHEATING TIME
150
°
C, 90 + 30 SEC.
2.5
°
C ± 0.5
°
C/SEC.
3
°
C + 1
°
C/- 0.5
°
C
TIGHT
TYPICAL
LOOSE
ROOM
TEMPERATURE
PREHEATING RATE 3
°
C + 1
°
C/- 0.5
°
C/SEC.
REFLOW HEATING RATE 2.5
°
C ± 0.5
°
C/SEC.
Note: Non-halide flux should be used.
217
°
C
RAMP-DOWN
6
°
C/SEC. MAX.
RAMP-UP
3
°
C/SEC. MAX.
150 - 200
°
C
260 +0/-5
°
C
t 25
°
C to PEAK
60 to 150 SEC.
20-40 SEC.
TIME WITHIN 5
°
C of ACTUAL
PEAK TEMPERATURE
t
p
t
s
PREHEAT
60 to 180 SEC.
t
L
T
L
T
smax
T
smin
25
T
p
TIME
TEMPERATURE
NOTES:
THE TIME FROM 25
°
C to PEAK TEMPERATURE = 8 MINUTES MAX.
T
smax
= 200
°
C, T
smin
= 150
°
C
Note: Non-halide flux should be used.
5
Regulatory Information
The devices contained in this data sheet have been approved by the following organizations:
UL
Recognized under UL 1577, Component Recognition
Program, File E55361.
CSA
Approved under CSA Component Acceptance Notice
#5, File CA 88324.
IEC/EN/DIN EN 60747-5-2
Approved under
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884
Teil 2):2003-01
(HCNW and Option 060 only)
Insulation and Safety Related Specications
8-Pin DIP Widebody
(300 Mil) SO-8 (400 Mil)
Parameter Symbol Value Value Value Units Conditions
Minimum External L(101) 7.1 4.9 9.6 mm Measured from input terminals
Air Gap (External to output terminals, shortest
Clearance) distance through air.
Minimum External L(102) 7.4 4.8 10.0 mm Measured from input terminals
Tracking (External to output terminals, shortest
Creepage) distance path along body.
Minimum Internal 0.08 0.08 1.0 mm Through insulation distance,
Plastic Gap conductor to conductor, usually
(Internal Clearance) the direct distance between the
photoemitter and photodetector
inside the optocoupler cavity.
Minimum Internal NA NA 4.0 mm Measured from input terminals
Tracking (Internal to output terminals, along
Creepage) internal cavity.
Tracking Resistance CTI 200 200 200 Volts DIN IEC 112/VDE 0303 Part 1
(Comparative
Tracking Index)
Isolation Group IIIa IIIa IIIa Material Group
(DIN VDE 0110, 1/89, Table 1)
Option 300 - surface mount classication is Class A in accordance with CECC 00802.
6
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (HCPL-2503 OPTION 060 ONLY)
Description Symbol Characteristic Units
Installation classication per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤300 V rms I-IV
for rated mains voltage ≤450 V rms I-III
Climatic Classication 55/100/21
Pollution Degree (DIN VDE 0110/1.89) 2
Maximum Working Insulation Voltage V
IORM
630 V
peak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production Test with t
m
= 1 sec, V
PR
1181 V
peak
Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
V
IORM
x 1.5 = V
PR
, Type and sample test, V
PR
945 V
peak
t
m
= 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage, t
ini
= 10 sec) V
IOTM
6000 V
peak
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Figure 9, Thermal Derating curve.)
Case Temperature T
S
175 °C
Input Current I
S,INPUT
230 mA
Output Power P
S,OUTPUT
600 mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
≥10
9
Ω

HCPL-2503#500

Mfr. #:
Manufacturer:
Broadcom / Avago
Description:
High Speed Optocouplers 1MBd 1Ch 25mA
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union