FCCx410QD3Cxx Product Specification – July 2016
Finisar Corporation – 16-Janunary-2016 Rev. A1 Page 4
III. Connectivity Diagnostics
®
Features
The FCCx410QD3Cxx Quadwire
®
are equipped with Finisar’s Connectivity
Diagnostics
®
, a technology solution enabling real-time performance monitoring and
troubleshooting. The following two features are implemented by default:
LynkFind
™
By manually pushing in the pull tab, both near- and far-end pull tabs will rapidly blink.
To reset the pull tab light off, simply push in the pull tab again on either end of the AOC.
LynkGuardian
™
If a digital diagnostic monitor (DDM) triggers an alarm or warning event, or upon a
transmitter fault or a receiver loss of signal, the pull tabs of both ends will light up as
follows: the near end (where the alarm originates) pull tab will blink slowly, while the far
end pull tab will glow solid. Both pull tab lights will alternate blinking and solid in case
DDM events occur on both AOCs ends.
IV. Absolute Maximum Ratings
Parameter Symbol Min Typ Max Unit Ref.
Maximum Supply Voltage Vcc1,
VccTx,
VccRx
-0.5 3.6 V
Storage Temperature T
S
-40 85
C
1
Case Operating Temperature T
OP
0 70
C
Relative Humidity RH 0 85 % 2
Notes:
1. Assumes no mechanical load force on the unit. Ensuring no mechanical load force requires a cable bend
radius of >105 mm within 100 mm of either cable end module and >60 mm on the rest of the cable.
2. Non-condensing.
V. Electrical Characteristics
(T
OP
= 0 to 70°
°°
°C, V
CC
= 3.3 ± 5% Volts)
Parameter Symbol Min Typ Max Unit Ref.
Supply Voltage Vcc1,
VccTx,
VccRx
3.15 3.45 V
Supply Current Icc 350 mA
Link Turn-On Time
Transmit Turn-On Time 2000 ms 1
Transmitter (per Lane)
Differential data input swing Vin,pp
180 1200 mVpp 2
Differential input threshold 50 mV
Receiver (per Lane)
Differential data output swing Vout,pp
0 800 mVpp 3,4
Power Supply Ripple Tolerance PSR
50 mVpp