FCCx410QD3Cxx Product Specification – July 2016
Finisar Corporation – 16-Janunary-2016 Rev. A1 Page 8
Power (mW)
Pre-Emphasis into 100ohms (mV)
0 125 175 325
Vo (mV)
0
599
317
751 935 971 1075
422
787 971 1007 1111
739
883 1055 1103 1190
Figure 5 – Power Dissipation (mW, maximum) vs. Rx Output Conditions
VII. Memory Map and Control Registers
Compatible with SFF-8436.
2
Please see Finisar Application Note AN-2075: Quadwire
®
EEPROM Mapping
3
for details.
VIII. Environmental Specifications
Finisar Quadwire
®
active optical cables have an operating temperature range from 0°C to
+70°C case temperature.
Environmental Specifications Symbol
Min Typ Max Units Ref.
Case Operating Temperature T
op
0 70 °C
Storage Temperature T
sto
-40 85 °C 1
1. Assumes no mechanical load force on the unit. Ensuring no mechanical load force requires a cable bend
radius of >105 mm within 100 mm of either cable end module and >60 mm on the rest of the cable.
IX. Regulatory Compliance
Finisar Quadwire
®
active optical cables are RoHS-6 Compliant. Copies of certificates are
available at Finisar Corporation upon request.
Quadwire
®
active optical cables are Class 1 laser eye safety compliant per IEC 60825-1.
The round cable jacket is available in both plenum-rated (OFNP) and riser-rated (OFNR)
low smoke zero-halogen (LSZH).