ADG4612/ADG4613
Rev. 0 | Page 6 of 24
Parameter 25°C −40°C to +85°C Unit Test Conditions/Comments
Break-Before-Make Time Delay, t
D
17 ns typ R
L
= 50 Ω, C
L
= 35 pF
(ADG4613 Only) 11 ns min V
S1
= V
S2
= 8 V; see Figure 26
Fault Response Time 250 ns typ V
S
= 9 V to 15 V, R
L
= 300 Ω, C
L
= 35 pF
Fault Recovery Time 1.4 μs typ V
S
= 9 V to 15 V, R
L
= 300 Ω, C
L
= 35 pF
Threshold Voltage, V
T
1.8 V typ
Charge Injection 292 pC typ V
S
= 6 V, R
S
= 0 Ω, C
L
= 1 nF; see Figure 27
Off Isolation −56 dB typ R
L
= 50 Ω, C
L
= 5 pF, f = 1 MHz; see Figure 28
Channel-to-Channel Crosstalk −74 dB typ R
L
= 50 Ω, C
L
= 5 pF, f = 1 MHz; see Figure 29
Total Harmonic Distortion + Noise, THD + N 0.26 % typ
R
L
= 110 Ω, 6 V p-p, f = 20 Hz to 20 kHz; see
Figure 31
Insertion Loss −0.27 dB typ R
L
= 50 Ω, C
L
= 5 pF; f = 1 MHz; see Figure 30
−3 dB Bandwidth 250 MHz typ R
L
= 50 Ω, C
L
= 5 pF; see Figure 30
C
S
(Off) 11.5 pF typ V
S
= 0 V, f = 1 MHz
C
D
(Off) 11.5 pF typ V
S
= 0 V, f = 1 MHz
C
D
(On), C
S
(On) 48 pF typ V
S
= 0 V, f = 1 MHz
POWER REQUIREMENTS
Normal Mode V
DD
= 13.2 V, V
SS
= 0 V
I
DD
90 μA typ Digital inputs = 0 V or V
DD
140 165 μA max
I
DD
600 μA typ Digital inputs = 5 V
660 900 μA max
Isolation Mode V
DD
= 13.2 V, V
SS
= 0 V or floating
I
DD
90 μA typ V
S
= 16 V or 1 V
140 165 μA max Digital inputs = 0 V or V
DD
1
Guaranteed by design, not subject to production test.