ADG4612/ADG4613
Rev. 0 | Page 8 of 24
Parameter 25°C −40°C to +85°C Unit Test Conditions/Comments
Channel-to-Channel Crosstalk −71 dB typ R
L
= 50 Ω, C
L
= 5 pF, f = 100 kHz; see Figure 29
Total Harmonic Distortion + Noise, THD + N 0.85 % typ
R
L
= 110 Ω, f = 20 Hz to 20 kHz, V
S
= 3.5 V p-p;
see Figure 31
Insertion Loss −0.5 dB typ R
L
= 50 Ω, C
L
= 5 pF; f = 1 MHz; see Figure 30
−3 dB Bandwidth 293
MHz
typ
R
L
= 50 Ω, C
L
= 5 pF; see Figure 30
C
S
(Off) 14 pF typ V
S
= 0 V, f = 1 MHz
C
D
(Off) 14 pF typ V
S
= 0 V, f = 1 MHz
C
D
(On), C
S
(On) 50 pF typ V
S
= 0 V, f = 1 MHz
POWER REQUIREMENTS
Normal Mode V
DD
= 5.5 V, V
SS
= 0 V
I
DD
90 μA typ Digital inputs = 0 V or V
DD
140 165 μA max
Isolation Mode V
DD
= 5.5 V, V
SS
= 0 V or floating
I
DD
90 μA typ Digital inputs = 0 V or 5.5 V
140 165 μA max V
S
= 1 V/16 V, V
D
= 16 V/1 V
1
Guaranteed by design, not subject to production test.
CONTINUOUS CURRENT PER CHANNEL, SX OR DX
Table 4.
Parameter 25°C 85°C Unit
CONTINUOUS CURRENT, Sx OR Dx
V
DD
= +5 V, V
SS
= −5 V
TSSOP (θ
JA
= 112°C/W) 109 52 mA maximum
LFCSP (θ
JA
= 48.7°C/W) 160 83 mA maximum
V
DD
= 12 V, V
SS
= 0 V
TSSOP (θ
JA
= 112°C/W) 113 56 mA maximum
LFCSP (θ
JA
= 48.7°C/W) 175 87 mA maximum
V
DD
= 5 V, V
SS
= 0 V
TSSOP (θ
JA
= 112°C/W) 78 39 mA maximum
LFCSP (θ
JA
= 48.7°C/W) 118 56 mA maximum
POWER SUPPLY OPERATION
Temperature range is −40°C to +105°C, unless otherwise noted.
Table 5.
Parameter Min Max Unit Comments
POWER SUPPLY
V
DD
to V
SS
16 V GND = 0 V
V
DD
2.7 16 V GND = 0 V
V
SS
−5.5 0 V GND = 0 V
DUAL SUPPLY
V
SS
/V
DD
−5.5 +10.5 V V
DD
to V
SS
= 16 V, GND = 0 V
SINGLE SUPPLY
V
DD
0 16 V V
DD
to V
SS
= 16 V, GND = 0 V, V
SS
= 0 V
Analog Signal Range, V
D
, V
S
Normal Mode −5.5 V
DD
V V
DD
to V
SS
= 16 V maximum
Isolation Mode −5.5 +16 V
Most negative (V
S
,V
D
, or V
SS
) to most positive
(V
S
,V
D
, Inx, or V
DD
) = 16 V maximum